OSHA Inspection: PCC AIRFOILS, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of PCC AIRFOILS, LLC in 3860 UNION AVENUE, MINERVA, OH 44657 (NAICS 331528). OSHA activity number 343591996.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch PCC Airfoils, LLC for free Get an email when a new federal OSHA severe-injury report for PCC Airfoils, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
PCC AIRFOILS, LLC
Site address
3860 UNION AVENUE
City
MINERVA
State
OH
ZIP
44657
Mailing
3860 UNION AVENUE, MINERVA, OH 44657
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Union (A)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331528
Employees
535
Ownership type
Private (A)

2 citations on file for this inspection.

1910.147 D

Deleted Serious Gravity 10 1 instance 26 exposed
Issued
Dec 21, 2018
Abate by
Jan 18, 2019
Penalty
Initial $12,934 · Current $0 Reduced
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6):  On or about October 27, 2018, employees were exposed to machine hazards associated with moving parts and rotating shafts during servicing and cleaning of the motor box on Baldor Electric Company- Lightnin Mixer F2 (SN F1607060913) located in the dip line department. The employer failed to implement energy control application steps as the machine was not shut down or turned off to perform the servicing  work [per the 1910.147(d)(2) requirements]. As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)(i)] , and verification of isolation [(d)(6)], were not implemented to protect employees from machine servicing hazards.
Recent events (2)
  • · I (S) $0
  • · Z (S) $12934

1910.212 A01

Serious Gravity 10 1 instance 26 exposed
Issued
Dec 21, 2018
Penalty
Initial $12,934 · Current $12,934
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  On or about October 27, 2018, employee(s) were exposed to machine hazards associated with unguarded moving parts and rotating shafts on Baldor Electric Company- Lightnin Mixer F2 (SN F1607060913) located in the dip line department.