Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MWM CONSTRUCTION, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MWM CONSTRUCTION, INC. in 746 DEMPSTER ST., MOUNT PROSPECT, IL 60056 (NAICS 238160). OSHA activity number 343596581.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch MWM Construction, INC. — free Get an email when a new federal OSHA severe-injury report for MWM Construction, INC. is published. One employer, no account, unsubscribe in one click.
Site address
746 DEMPSTER ST.
City
MOUNT PROSPECT
State
IL
ZIP
60056
Mailing
5516 W. AGATITE AVE., CHICAGO, IL 60630
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
5
Ownership type
A

7 citations on file for this inspection.

1903.19 C01

Other-than-serious 1 instance 1 exposed
Issued
Apr 23, 2019
Abate by
May 24, 2019
Penalty
Initial $319 · Current $319
29 CFR 1903.19(c)(1): The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated:   MWM Construction, Inc., failed to certify to OSHA within 10 calendar days after the abatement date that each of the following cited violations had been corrected:   Citation Number            Item Number                    Abatement Date  01                                01                                   01/09/2019  01                                03                                   02/21/2019     In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF THE CORRECTIVE ACTION WORKSHEET).
Recent events (1)
  • — Z (O) $319

1926.100 A

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 3, 2019
Abate by
Jan 9, 2019
Penalty
Initial $2,217 · Current $2,217
29 CFR 1926.100(a): Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.  On or about November 13, 2018, an employee was exposed to struck-by hazards while performing ground work below roofing activities.  The employee on the ground was not wearing a hard hat.
Recent events (1)
  • — Z (S) $2217

1926.501 B03

Serious Gravity 10 1 instance 1 exposed
Issued
Jan 3, 2019
Penalty
Initial $3,880 · Current $3,880
29 CFR 1926.501(b)(3): "Hoist areas." Each employee in a hoist area shall be protected from falling 6 feet (1.8 m) or more to lower levels by guardrail systems or personal fall arrest systems. If guardrail systems, [or chain, gate, or guardrail] or portions thereof, are removed to facilitate the hoisting operation (e.g., during landing of materials), and an employee must lean through the access opening or out over the edge of the access opening (to receive or guide equipment and materials, for example), that employee shall be protected from fall hazards by a personal fall arrest system.  On or about November 13, 2018, an employee was exposed to fall hazards while working in a hoist area on the roof without a guardrail or personal fall arrest system.
Recent events (1)
  • — Z (S) $3880

1926.501 B10

Serious Gravity 10 1 instance 3 exposed
Issued
Jan 3, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.501(b)(10): "Roofing work on Low-slope roofs." Except as otherwise provided in paragraph (b) of this section, each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels shall be protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width (see Appendix A to subpart M of this part), the use of a safety monitoring system alone [i.e. without the warning line system] is permitted.  On or about November 13, 2018, employees were exposed to fall hazards while performing roofing work at the edge of a low slope roof without guardrails, safety nets, warning lines, or personal fall protection systems.
Recent events (1)
  • — Z (S) $0

1926.503 A01

Serious Gravity 5 1 instance 4 exposed
Issued
Jan 3, 2019
Abate by
Feb 21, 2019
Penalty
Initial $2,772 · Current $2,772
29 CFR 1926.503(a)(1): The employer shall provide a training program for each employee who might be exposed to fall hazards. The program shall enable each employee to recognize the hazards of falling and shall train each employee in the procedures to be followed in order to minimize these hazards.  On or about November 13, 2018, employees were exposed to fall hazards while working on a low slope roof.  Employees were not trained to recognize the hazards of working at heights or on the procedures to minimize fall hazards.
Recent events (1)
  • — Z (S) $2772

1926.404 F06

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 3, 2019
Penalty
Initial $2,217 · Current $2,217
29 CFR 1926.404(f)(6): Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent and continuous.  On or about November 13, 2018, employees were exposed to electrical hazards while working with an extension cord that was missing the grounding prong.
Recent events (1)
  • — Z (S) $2217

1926.405 G01 III C

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 3, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.405(g)(1)(iii)(C): Where run through doorways, windows, or similar openings, except as permitted in paragraph (a)(2)(ii)(1) of this section;  On or about November 13, 2018, employees were exposed to electrical hazards while working with an extension cord that was run through doorways in which the doors were allowed to close on the cord.
Recent events (1)
  • — Z (S) $0

View MWM Construction, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343596581.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.