Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ICF PANELS, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of ICF PANELS, LLC in 10 HALLENBECK HILL, EAST GREENBUSH, NY 12061 (NAICS 236115). OSHA activity number 343693586.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch ICF Panels, LLC — free Get an email when a new federal OSHA severe-injury report for ICF Panels, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
ICF PANELS, LLC
Site address
10 HALLENBECK HILL
City
EAST GREENBUSH
State
NY
ZIP
12061
Mailing
202A GLENVILLE INDUSTRIAL PARK, GLENVILLE, NY 12302
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236115
Employees
14
Ownership type
A

7 citations on file for this inspection.

1926.100 A

Serious Gravity 1 1 instance 3 exposed
Issued
Apr 9, 2019
Abate by
Apr 15, 2019
Penalty
Initial $2,273 · Current $1,364 Reduced
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:  a) Worksite - On or prior to January 4, 2019, employees were not provided with hard hats potentially exposing them to struck by hazards from debris, materials, and equipment.
Recent events (3)
  • — F (S) $1363.8
  • — C (S) $2273
  • — Z (S) $2273

1926.501 B13

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 9, 2019
Abate by
Apr 15, 2019
Penalty
Initial $3,789 · Current $2,273 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):  a) Worksite - On or prior to January 4, 2019, employees were exposed to fall hazards due to working on the 2nd floor drilling holes for rebar approximately 10 feet 3 inch in height of the residential home without fall protection.
Recent events (3)
  • — F (S) $2273.4
  • — C (S) $3789
  • — Z (S) $3789

1926.502 B03

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 9, 2019
Abate by
Apr 15, 2019
Penalty
Initial $3,789 · Current $2,273 Reduced
29 CFR 1926.502(b)(3): Guardrail systems were not capable of withstanding, without failure, a force of at least 200 pounds (890 N) applied within 2 inches (5.1 cm) of the top edge, in any outward or downward direction, at any point along the top edge:  a) 1st floor red tape rail area - On or about December 27, 2018, an employee was exposed to fall hazards of approximately 14 feet when working approximately 3 feet away from the edge of an area on the 1st floor with an inadequate guardrail system in place that was not capable of withstanding of 200 lbs.
Recent events (3)
  • — F (S) $2273.4
  • — C (S) $3789
  • — Z (S) $3789

1926.503 A01

Serious Gravity 5 2 instances 3 exposed
Issued
Apr 9, 2019
Abate by
Apr 15, 2019
Penalty
Initial $3,789 · Current $2,273 Reduced
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards:  a) 2nd floor area of worksite - On or about January 4, 2019, employees were not provided fall protection training exposing employees to fall hazards when working on the 2nd floor drilling holes for rebar approximately 10 feet 3 inch in height of the residential home without fall protection.  b) 1st floor red tape rail area - On or about December 27, 2018, an employee was not provided fall protection training exposing the employee to fall hazards of approximately 14 feet when working approximately 3 feet away from the edge of an area on the 1st floor with an inadequate guardrail system in place.
Recent events (3)
  • — F (S) $2273.4
  • — C (S) $3789
  • — Z (S) $3789

1926.1053 A02

Serious Gravity 5 1 instance 3 exposed
Issued
Apr 9, 2019
Abate by
Apr 15, 2019
Penalty
Initial $3,031 · Current $1,819 Reduced
29 CFR 1926.1053(a)(2): Ladder rungs, cleats, and/or steps were not parallel, level, and uniformly spaced when the ladder was in position for use:  a) Outside Garage Area - On or about January 4, 2019, employees were exposed to fall hazards of approximately 4 feet due to accessing the garage using a 4 foot Werner self-supporting step ladder as a non-self-supporting ladder with ladder steps not level when the ladder was in position for use.
Recent events (3)
  • — F (S) $1818.6
  • — C (S) $3031
  • — Z (S) $3031

1926.1053 B01

Serious Gravity 5 2 instances 3 exposed
Issued
Apr 9, 2019
Abate by
Apr 15, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:  a) Garage Area - On or about January 4, 2019, employees were exposed to fall hazards of approximately 12 feet due to accessing the 2nd floor using a 12 foot Werner self-supporting step ladder that was extended approximately 1 foot above the upper landing surface of the 2nd floor.  b) Outside Garage Area - On or about January 4, 2019, employees were exposed to fall hazards of approximately 4 feet due to accessing the garage using a 4 foot Werner self-supporting step ladder that was extended approximately one inch above the upper landing surface of the garage floor.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1926.1053 B04

Serious Gravity 5 2 instances 3 exposed
Issued
Apr 9, 2019
Abate by
Dec 16, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed:  a) Garage Area - On or about January 4, 2019, employees were exposed to fall hazards of approximately 12 feet due to accessing the 2nd floor using a 12 foot Werner self-supporting step ladder as a non-self-supporting ladder.  b) Outside Garage Area - On or about January 4, 2019, employees were exposed to fall hazards of approximately 4 feet due to accessing the garage using a 4 foot Werner self-supporting step ladder as a non-self-supporting ladder.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

View ICF Panels, LLC's full OSHA safety record →