GLENVILLE, NY —
OSHA Inspection: ICF PANELS, LLC
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of ICF PANELS, LLC in 202A GLENVILLE INDUSTRIAL PARK, GLENVILLE, NY 12302 (NAICS 493110). OSHA activity number 343694048.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ICF PANELS, LLC
- Site address
- 202A GLENVILLE INDUSTRIAL PARK
- City
- GLENVILLE
- State
- NY
- ZIP
- 12302
- Mailing
- 202A GLENVILLE INDUSTRIAL PARK, GLENVILLE, NY 12302
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 493110
- Employees
- 14
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.134 C01
- Issued
- Apr 9, 2019
- Abate by
- May 13, 2019
- Penalty
- Initial $3,031 · Current $1,819 Reduced
General-duty citation text
29 CFR 1910.134(c)(1): In the workplace where respirators were necessary to protect the health of the employee or where respirators were required by the employer, the employer did not establish and implement a written respiratory protection program with worksite-specific procedures including the provisions (i)-(ix) of this section, as applicable: (a) On and before 1/4/2019, in the welding area, for the welder wearing a 3M half-face respirator with P100 cartridges while welding. The employer did not implement a worksite-specific respiratory protection program. Abatement Note: The Respiratory Protection Program shall include the following sections: (1) Procedures for selecting respirators for use in the workplace; (2) Medical evaluations of employees required to use respirators; (3) Fit testing procedures for tight-fitting respirators; (4) Procedures for proper use of respirators in routine and reasonably foreseeable emergency situations; (5) Procedures and schedules for cleaning, disinfecting, storing, inspecting, repairing, discarding, and otherwise maintaining respirators; (6) Procedures to ensure adequate air quality, quantity, and flow of breathing air for atmosphere- supplying respirators (if used); (7) Training of employees in the respiratory hazards to which they are potentially exposed during routine and emergency situations; (8) Training of employees in the proper use of respirators, including putting on and removing them, any limitations on their use, and their maintenance; and (9) Procedures for regularly evaluating the effectiveness of the program.
Recent events (3)
- — F (S) $1818.6
- — C (S) $3031
- — Z (S) $3031
1910.134 E01
- Issued
- Apr 9, 2019
- Abate by
- Apr 29, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee is fit tested or required to use the respirator in the workplace: (a) On and before 1/4/2019, in the welding area, for the welder wearing a 3M half-face respirator with P100 cartridges while welding. The employee was not provided a medical evaluation prior to being required to wear the respirator.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.134 H02 I
- Issued
- Apr 9, 2019
- Abate by
- Apr 17, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(h)(2)(i): Respirators were not stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals: (a) On and before 1/4/2019, in the welding area, for the welder wearing a 3M half-face respirator with P100 cartridges while welding. The employer did not implement storage procedures, respirators were hanging on a rack in the plating room.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.157 G02
- Issued
- Apr 9, 2019
- Abate by
- Dec 24, 2019
- Penalty
- Initial $3,789 · Current $2,273 Reduced
General-duty citation text
29 CFR 1910.157(g)(2): The employer did not provide hands on fire extinguisher training required in paragraph (g)(1) of this section upon initial employment and at least annually thereafter: (a) On or about 1/4/2019, at the facility, for the employees that are required to use the portable fire extinguishers in the event of a small fire, the employer did not provide hands on training.
Recent events (3)
- — F (S) $2273.4
- — C (S) $3789
- — Z (S) $3789
1910.1200 E01
- Issued
- Apr 9, 2019
- Abate by
- May 13, 2019
- Penalty
- Initial $3,789 · Current $2,273 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): Employer did not develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, material safety data sheets, and employee information and training will be met, and which also includes the following: (a) On and before 1/4/2019, at facility, for the employees exposed to Acetone, R- Guard, and Welding Fumes. Employer did not develop a hazard communication program.
Recent events (3)
- — F (S) $2273.4
- — C (S) $3789
- — Z (S) $3789
1910.1200 G08
- Issued
- Apr 9, 2019
- Abate by
- Apr 17, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(g)(8): The employer did not ensure that Safety Data Sheets were readily accessible during each work shift to employees when they were in their work area(s): (a) On and before 1/4/2019, at facility, employees could not readily access the SDS's. The facility has chemicals such as, but not limited to, Acetone, R- Guard, and Welding Fumes.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.1200 H01
- Issued
- Apr 9, 2019
- Abate by
- Apr 29, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: (a) On and before 1/4/2019, at facility, for the employees exposed to Acetone, R- Guard, and Welding Fumes. Training was not provided to employees regarding chemical hazards.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.134 F02
- Issued
- Apr 9, 2019
- Abate by
- Apr 29, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(2): The employer did not ensure that employees using tight fitting face piece respirators pass an appropriate qualitative or quantitative fit test prior to initial use of the respirator, whenever a different respirator facepiece (size, style, model or make) is used, and at least annually thereafter. (a) On and before 1/4/2019, in the welding area, for the welder wearing a 3M half-face respirator with P100 cartridges while welding. The employees were not fit tested, either qualitatively or quantitatively, prior to being required to use this respirator by the employer.
Recent events (3)
- — F (O) $0
- — C (O) $0
- — Z (O) $0
More inspections at ICF Panels, LLC
View ICF Panels, LLC's full OSHA safety record →
More inspections in this industry (NAICS 493110)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343694048.