Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ICF PANELS, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of ICF PANELS, LLC in 202A GLENVILLE INDUSTRIAL PARK, GLENVILLE, NY 12302 (NAICS 493110). OSHA activity number 343693651.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch ICF Panels, LLC — free Get an email when a new federal OSHA severe-injury report for ICF Panels, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
ICF PANELS, LLC
Site address
202A GLENVILLE INDUSTRIAL PARK
City
GLENVILLE
State
NY
ZIP
12302
Mailing
202A GLENVILLE INDUSTRIAL PARK, GLENVILLE, NY 12302
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
493110
Employees
14
Ownership type
A

6 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 9, 2019
Abate by
Dec 16, 2019
Penalty
Initial $3,789 · Current $2,273 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that an employee was exposed to struck-by hazards due to using a below-the-hook lifting device without the proper markings, construction, and installation:  a) Warehouse - On or prior to December 4, 2018, employees were exposed to struck-by hazards when working around a below-the-hook lifting device (spreader bar made in-house) that was not tested or load rated.   The below-the-hook lifting device is used to lift approximately 600-1500 lb walls and did not have any markings.
Recent events (3)
  • — F (S) $2273.4
  • — C (S) $3789
  • — Z (S) $3789

1910.28 B01 I

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 9, 2019
Abate by
Dec 16, 2019
Penalty
Initial $3,789 · Current $2,273 Reduced
29 CFR 1910.28(b)(1)(i): The employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that was 4 feet (1.2 m) or more above a lower level was protected from falling by one or more of the following:    a) Warehouse - On or about December 4, 2018, employees were exposed to fall hazards of approximately 12 feet due to working on top of the walls bracing the walls together without fall protection.
Recent events (3)
  • — F (S) $2273.4
  • — C (S) $3789
  • — Z (S) $3789

1910.30 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 9, 2019
Abate by
Dec 16, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.30(a)(1): The employer did not provide training to each employee who uses personal fall protection systems or who is required to be trained as specified elsewhere in this subpart prior to being exposed to a fall hazard:  a) Warehouse - On or prior to January 4, 2019, employees were not provided training in fall protection.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.135 A01

Serious Gravity 1 1 instance 2 exposed
Issued
Apr 9, 2019
Abate by
Dec 16, 2019
Penalty
Initial $2,273 · Current $1,364 Reduced
29 CFR 1910.135(a)(1): The employer did not ensure that each affected employee wear a protective helmet when working in areas where there is a potential for injury to the head from falling objects:  a) Warehouse - On or prior to January 4, 2019, employees were not provided hard hats when working around and lifting walls with a crane.
Recent events (3)
  • — F (S) $1363.8
  • — C (S) $2273
  • — Z (S) $2273

1910.303 B02

Other-than-serious 1 instance 11 exposed
Issued
Apr 9, 2019
Abate by
Dec 16, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  a) Warehouse - On or about January 4, 2019, a relocatable power tap (RPT) or power strip powering various electrical equipment was not installed and used in accordance with instruction in the listing, labeling, or certification such as, but not limited to, being permanently secured to a wall and used as a substitute for fixed wiring.
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

1910.305 G01 IV A

Other-than-serious 1 instance 11 exposed
Issued
Apr 9, 2019
Abate by
Dec 16, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  a) Warehouse - On or about January 4, 2019, extension cords were plugged into various outlets, extensions, and a relocatable power tap (RPT) being used as permanent wiring powering various equipment.
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

View ICF Panels, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343693651.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.