WILKES BARRE, PA —
OSHA Inspection: INTERMETRO INDUSTRIES CORPORATION
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of INTERMETRO INDUSTRIES CORPORATION in 1001 NORTH WASHINGTON STREET, WILKES BARRE, PA 18705 (NAICS 336999). OSHA activity number 343694980.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- INTERMETRO INDUSTRIES CORPORATION
- Site address
- 1001 NORTH WASHINGTON STREET
- City
- WILKES BARRE
- State
- PA
- ZIP
- 18705
- Mailing
- 651 NORTH WASHINGTON STREET, WILKES BARRE, PA 18705
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336999
- Employees
- 365
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.101 C
- Issued
- Mar 26, 2019
- Abate by
- Apr 29, 2019
- Penalty
- Initial $5,314 · Current $0 Reduced
General-duty citation text
29 CFR 1910.101(c): Compressed gas cylinders, portable tanks, and cargo tanks did not have pressure relief devices installed and maintained in accordance with Compressed Gas Association Pamphlets S-1.1-1963 and 1965 addenda and S-1.2-1963: a) Foaming department, DOT portable tanks, used as pressurized tanks, had pressure relief devices which were not examined by the lead operators to ensure that the device protective covers were not adhered to the device components which may inhibit timely actuation of the devices in the event of over-pressurization, on or about, January 8, 2019. b) Foaming department, DOT portable tanks, used as pressurized tanks, had pressure relief devices which were not examined by the lead operators to ensure that the exhaust ports of the devices were not coated with paint or other coating which may limit the relief capacity of the devices in the event of over-pressurization, on or about, January 8, 2019. ABATEMENT CERIFICATION REQUIRED
Recent events (3)
- — F (S) $0
- — C (S) $5314
- — Z (S) $5314
1910.303 B01 II
- Issued
- Mar 26, 2019
- Abate by
- Apr 29, 2019
- Penalty
- Initial $5,314 · Current $0 Reduced
General-duty citation text
29 CFR 1910.303(b)(1)(ii): Electrical equipment was not free from recognized hazards, based on the mechanical strength and durability, including, for parts designed to enclose and protect other equipment, the adequacy of the protection thus provided: a) Zinc plating area, metal electrical enclosures, were observed to be heavily corroded such that large scales of rust had formed, thus weakening the structure, on or about, January 8, 2019. b) Zinc plating area, metal surface-switch retaining rings that were mounted on metal electrical enclosures, were observed to be heavily corroded such that the protective rubber switch covers had fallen off, thus leaving potential vapor openings into the enclosure, and weakening the ability of the enclosure to hold the switch in place, on or about, January 8, 2019. a) Tin room, a metal electrical enclosure, was observed to be heavily corroded such that large scales of rust had formed, thus weakening the structure, and creating an opening into the box near the wall, on or about, January 8, 2019. ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
- — F (S) $0
- — C (S) $5314
- — Z (S) $5314
1910.1200 H03 I
- Issued
- Mar 26, 2019
- Abate by
- Apr 29, 2019
- Penalty
- Initial $0 · Current $0
1900
General-duty citation text
29 CFR 1910.1200(h)(3)(i): The employee training did not include the methods and observations used to detect the presence or release of a hazardous chemical in the work area: a) Foaming Department, the lead operators who periodically entered the tank storage room, had no method to determine if the nitrogen gas used in the process, had inadvertently leaked into the small enclosed room and created an oxygen deficient atmosphere via displacement, on or about, January 8, 2019. ABATEMENT CERTIFICATION REQUIRED.
Recent events (3)
- — F (O) $0
- — C (O) $0
- — Z (O) $0
More inspections at Intermetro Industries Corporation
View Intermetro Industries Corporation's full OSHA safety record →
More inspections in this industry (NAICS 336999)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343694980.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.