ATLANTA, GA —
OSHA Inspection: DENNIS TAYLOR AND CO., INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of DENNIS TAYLOR AND CO., INC. in 3475 PIEDMONT RD., ATLANTA, GA 30305 (NAICS 532412). OSHA activity number 343699997.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DENNIS TAYLOR AND CO., INC.
- Site address
- 3475 PIEDMONT RD.
- City
- ATLANTA
- State
- GA
- ZIP
- 30305
- Mailing
- 1420 OAKLAND ROAD, LAWRENCEVILLE, GA 30044
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 532412
- Employees
- 9
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.651 B04
- Issued
- Jul 3, 2019
- Abate by
- Jul 30, 2019
- Penalty
- Initial $11,934 · Current $0 Reduced
General-duty citation text
29 CFR 1926.651(b)(4): While the excavation was opened, underground installations were not protected, supported or removed as necessary to safeguard employees: a) 3475 Piedmont Rd, Atlanta (Construction site) - On or about 1/7/2019, the employer exposed employees to electrical shock and arch flash hazards in that the underground energized electrical power lines were not protected from contact while employees were inside an open excavation cutting and removing three underground power lines to install a new 8 inch ductile iron pipe water supply line inside the trench.
Recent events (2)
- — I (S) $0
- — Z (S) $11934
1926.416 A03
- Issued
- Jul 3, 2019
- Abate by
- Jul 30, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.416(a)(3): Before work was begun the employer did not ascertain by inquiry or direct observation, or by instruments, whether any part of an energized electric power circuit, exposed or concealed, was so located that the performance of the work may bring any person, tool, or machine into physical or electrical contact with the electric power circuit. The employer did not post and maintain proper warning signs where such a circuit exists. The employer did not advise employees of the location of such lines, the hazards involved, and the protective measures to be taken. a) 3475 Piedmont Rd, Atlanta (Construction site) - On or about 1/7/2019, the employer exposed employees to electrical shock and arch flash hazards in that the employer did not post and maintain proper warning signs for underground power lines and neither advised employees of the location of such lines, the hazards involved, and the protective measures to be taken while employees were inside an open excavation cutting and removing three underground power lines to install a new 8 inch ductile iron pipe water supply line inside the trench.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Dennis Taylor and CO., INC.
View Dennis Taylor and CO., INC.'s full OSHA safety record →
More inspections in this industry (NAICS 532412)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343699997.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.