BEVERLY, OH —
OSHA Inspection: WATERFORD TANK & FABRICATION, LTD
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of WATERFORD TANK & FABRICATION, LTD in 203 STATE ROUTE 83, BEVERLY, OH 45715 (NAICS 332420). OSHA activity number 343735916.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- WATERFORD TANK & FABRICATION, LTD
- Site address
- 203 STATE ROUTE 83
- City
- BEVERLY
- State
- OH
- ZIP
- 45715
- Mailing
- P.O. BOX 392, LOWELL, OH 45744
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332420
- Employees
- 90
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.147 C04 II
- Issued
- Mar 11, 2019
- Abate by
- Mar 21, 2019
- Penalty
- Initial $9,282 · Current $7,426 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, the following: a. On or before January 17, 2019, where an employee locked out a Peddiworker 1050 hydraulic power press, procedures were not developed, documented and utilized for the control of potentially hazardous energy, thereby exposing employees to a caught-in hazard.
Recent events (2)
- — I (S) $7425.6
- — Z (S) $9282
1910.147 C06 I
- Issued
- Mar 11, 2019
- Abate by
- Mar 29, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed. a. On or before January 17, 2019, where an employee locked out a Peddiworker 1050 hydraulic power press, periodic inspections were not conducted at least annually, thereby exposing employees to caught-in hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 D02
- Issued
- Mar 11, 2019
- Abate by
- Mar 29, 2019
- Penalty
- Initial $9,282 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(d)(2): Machine or equipment shutdown. The machine or equipment shall be turned off or shut down using the procedures established for the machine or equipment. An orderly shutdown must be utilized to avoid any additional or increased hazard(s) to employees as a result of the equipment stoppage. a. On or before January 17, 2019, where employees changed out the tooling on a Peddiworker 1050 hydraulic power press, the press was not turned off or shut down using established procedures, thereby exposing employees to a caught-in hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $9282
1910.212 A01
- Issued
- Mar 11, 2019
- Abate by
- Mar 29, 2019
- Penalty
- Initial $9,282 · Current $7,426 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices,electronic safety devices, etc. a. On or before January 17, 2019, where employees operated a Peddiworker 1050 hydraulic power press, the Punching Unit of the press was not guarded, thereby exposing employees to caught-in hazards. b. On or before January 17, 2019, where employees operated a Peddiworker 1050 hydraulic power press, the Section and Bar Stock Shears of the press was not guarded on the machines right side, thereby exposing employees to caught-in hazards.
Recent events (2)
- — I (S) $7425.6
- — Z (S) $9282
1910.305 G02 III
- Issued
- Mar 11, 2019
- Abate by
- Mar 21, 2019
- Penalty
- Initial $6,630 · Current $5,304 Reduced
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables shall be connected to devices and fittings so that strain relief is provided that will prevent pull from being directly transmitted to joints or terminal screws. a. On or before January 17, 2019, where employees operated a Peddiworker 1050 hydraulic power press, the electrical power cord was not adequately secured at the machine, thereby exposing employees to a 480 volt electrical contact hazard.
Recent events (2)
- — I (S) $5304
- — Z (S) $6630
More inspections at Waterford Tank & Fabrication, LTD
View Waterford Tank & Fabrication, LTD's full OSHA safety record →
More inspections in this industry (NAICS 332420)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343735916.