LAKESIDE, CA —
OSHA Inspection: BARONA CASINO & RESORT
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of BARONA CASINO & RESORT in 1932 WILDCAT CANYON ROAD, LAKESIDE, CA 92040 (NAICS 721120). OSHA activity number 343741625.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BARONA CASINO & RESORT
- Site address
- 1932 WILDCAT CANYON ROAD
- City
- LAKESIDE
- State
- CA
- ZIP
- 92040
- Mailing
- 1932 WILDCAT CANYON ROAD, LAKESIDE, CA 92040
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 721120
- Employees
- 3000
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.215 A04
- Issued
- Feb 21, 2019
- Abate by
- Feb 27, 2019
- Penalty
- Initial $4,831 · Current $3,382 Reduced
General-duty citation text
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch: Butler Bldg., Plumbing Shop: A Westward 6" bench grinder (MD.# 4TM70) used for smoothing metal parts, had a gap in excess of 1/4" between the work rest and the grinding wheel. Employees were exposed to caught-in hazards.
Recent events (2)
- — I (S) $3381.7
- — Z (S) $4831
1910.215 B09
- Issued
- Feb 21, 2019
- Abate by
- Mar 7, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: In the following locations, bench grinders were missing tongue guards. Employees are exposed to impalement hazards. a. Plumbing Shop: A Westward 6" bench grinder (MD.# 4TM70) on the left side b. Fabrication Shop: A Baldor bench grinder (SN P1198)
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.253 B04 III
- Issued
- Feb 21, 2019
- Abate by
- Feb 27, 2019
- Penalty
- Initial $6,440 · Current $3,832 Reduced
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet: Butler Bldg., compressed gas storage cage: Numerous oxygen and acetylene cylinders used for welding operations were stored together. Employees were exposed to explosion and struck-by hazards.
Recent events (2)
- — I (S) $3831.8
- — Z (S) $6440
1910.303 B02
- Issued
- Feb 21, 2019
- Abate by
- Mar 18, 2019
- Penalty
- Initial $6,440 · Current $4,508 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: Butler Bldg., Plumbing Shop: Stationary electrical equipment (refrigerator, microwave, chargers) was energized by a power tab instead of an approved wall outlet. Employees were exposed to shock hazards.
Recent events (2)
- — I (S) $4508
- — Z (S) $6440
1910.305 G01 IV B
- Issued
- Feb 21, 2019
- Abate by
- Mar 18, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(B): Flexible cords and/or cables were run through holes in walls, ceilings, or floors: Butler Bldg., Plumbing Shop: A power tab cord used to energize stationary electrical equipment (refrigerator, microwave, chargers) had the cord run through a hole into an adjoining room. Employees were exposed to fire hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.94 C04 IV
- Issued
- Feb 21, 2019
- Abate by
- Mar 18, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.94(c)(4)(iv): Spray rooms used for production spray-finishing operations shall conform to the requirements for spray booths. Butler Bldg., Fabrication Shop: Flammable paints and thinners are used in the spray room to coat materials, generating flammable vapor and mist. The spray room was not outfitted with a gauge ensuring the minimum maintained velocity of air movement required for health and safety. Spray booths shall be designed and constructed in accordance with �� 1910.107(b)(1) through (b)(4) and (b)(6) through (b)(10). For a more detailed discussion of fundamentals relating to this subject, see ANSI Z9.2-1960, which is incorporated by reference as specified in �� 1910.6.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Barona Casino & Resort
View Barona Casino & Resort's full OSHA safety record →
More inspections in this industry (NAICS 721120)
More inspections in CA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343741625.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.