Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: UTICA METAL PRODUCTS, INC.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of UTICA METAL PRODUCTS, INC. in 1526 LINCOLN AVENUE, UTICA, NY 13502 (NAICS 336370). OSHA activity number 343774527.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Utica Metal Products, INC. — free Get an email when a new federal OSHA severe-injury report for Utica Metal Products, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1526 LINCOLN AVENUE
City
UTICA
State
NY
ZIP
13502
Mailing
1526 LINCOLN AVENUE, UTICA, NY 13502
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336370
Employees
82
Ownership type
A

3 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 10 1 instance 3 exposed
Issued
May 13, 2019
Penalty
Initial $9,282 · Current $6,962 Reduced

Hazardous substances 2260

29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section    a) Waste treatment area near plating line, on or about 2/7/19: Energy control procedures were not developed for changing transfer pump in system containing caustic sodium hydroxide under pressure.
Recent events (2)
  • — I (S) $6961.5
  • — Z (S) $9282

1910.147 C07 I

Serious Gravity 10 1 instance 3 exposed
Issued
May 13, 2019
Penalty
Initial $0 · Current $0

Hazardous substances 2260

29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees:  a) Waste treatment area near plating line, on or about 2/7/19: Training on energy control procedures was not performed for the task of changing the transfer pump in a system containing caustic sodium hydroxide under pressure.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 D03

Serious Gravity 10 1 instance 3 exposed
Issued
May 13, 2019
Penalty
Initial $9,282 · Current $6,962 Reduced

Hazardous substances 2260

29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s):    a) Waste treatment area near plating line, on or about 2/7/19: Energy isolating devices were not applied on equipment for the task of changing the transfer pump in a system containing caustic sodium hydroxide under pressure.
Recent events (2)
  • — I (S) $6961.5
  • — Z (S) $9282

View Utica Metal Products, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343774527.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.