Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: NIMSGERN STEEL CORP

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of NIMSGERN STEEL CORP in 8765 FRANK DR., MINOCQUA, WI 54548 (NAICS 332312). OSHA activity number 343778692.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Nimsgern Steel Corp — free Get an email when a new federal OSHA severe-injury report for Nimsgern Steel Corp is published. One employer, no account, unsubscribe in one click.
Establishment
NIMSGERN STEEL CORP
Site address
8765 FRANK DR.
City
MINOCQUA
State
WI
ZIP
54548
Mailing
8765 FRANK DR., MINOCQUA, WI 54548
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332312
Employees
30
Ownership type
A

6 citations on file for this inspection.

1910.106 E02 II

Serious Gravity 1 1 instance 10 exposed
Issued
Jul 24, 2019
Abate by
Aug 21, 2019
Penalty
Initial $3,978 · Current $2,785 Reduced

Hazardous substances 2590

29 CFR 1910.106(e)(2)(ii): "Containers." Flammable liquids shall be stored in tanks or closed containers.    On or about February 11, 2019, the flammable liquid Xylol was not stored in a closed container.  The employer had a five gallon container of Xylol that had a shop towel stuffed in the bung hole sitting in the Paint Department at the North end of the Welding Shop.
Recent events (2)
  • — I (S) $2784.6
  • — Z (S) $3978

1910.107 B10

Serious Gravity 1 1 instance 10 exposed
Issued
Jul 24, 2019
Abate by
Aug 21, 2019
Penalty
Initial $3,978 · Current $2,785 Reduced
29 CFR 1910.107(b)(10): Illumination. When spraying areas are illuminated through glass panels or other transparent materials, only fixed lighting units shall be used as a source of illumination. Panels shall effectively isolate the spraying area from the area in which the lighting unit is located, and shall be of a noncombustible material of such a nature or so protected that breakage will be unlikely. Panels shall be so arranged that normal accumulations of residue on the exposed surface of the panel will not be raised to a dangerous temperature by radiation or conduction from the source of illumination.    On or about February 11, 2019, the spray area in the Paint Department did not have panels separating the spraying area from the lighting units.
Recent events (2)
  • — I (S) $2784.6
  • — Z (S) $3978

1910.134 G01 I A

Serious Gravity 1 1 instance 1 exposed
Issued
Jul 24, 2019
Penalty
Initial $3,978 · Current $2,785 Reduced
29 CFR 1910.134(g)(1)(i)(A): The employer shall not permit respirators with tight-fitting facepieces to be worn by employees who have facial hair that comes between the sealing surface of the facepiece and the face or that interferes with valve function.  On or about March 19, 2019, the employer did not ensure that the employee wearing a full-face respirator did not have facial hair that came between the sealing surface and their face.
Recent events (2)
  • — I (S) $2784.6
  • — Z (S) $3978

1910.334 A02 I

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 24, 2019
Abate by
Aug 21, 2019
Penalty
Initial $6,630 · Current $4,641 Reduced
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) shall be visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket). Cord and plug connected equipment and flexible cord sets (extension cords) which remain connected once they are put in place and are not exposed to damage need not be visually inspected until they are relocated.    On or about February 11, 2019, the power cord on the electric pedestal fan at the South end of the Paint Department had not been visually inspected before the shift.  The power cord was visibly damaged and missing the ground pin which exposed employees to electric shock.
Recent events (2)
  • — I (S) $4641
  • — Z (S) $6630

1910.334 A03 I

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 24, 2019
Abate by
Aug 21, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.334(a)(3)(i): A flexible cord used with grounding type equipment shall contain an equipment grounding conductor.    On or about February 11, 2019, the power cord on the electric pedestal fan at the South end of the Paint Department was missing the ground pin.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 F06

Other-than-serious 2 instances 1 exposed
Issued
Jul 24, 2019
Abate by
Aug 21, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(f)(6)(ii): Workplace labeling. Except as provided in paragraphs (f)(7) and (f)(8) of this section, the employer shall ensure that each container of hazardous chemicals in the workplace is labeled, tagged or marked with either product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals, and which, in conjunction with the other information immediately available to employees under the hazard communication program, will provide employees with the specific information regarding the physical and health hazards of the hazardous chemical.    On or about February 11, 2019, the employer did not ensure that two disposable plastic bottles of chemicals used to lubricate the drills in the Fabrication Shop were labeled, tagged or marked with product identifier and words, pictures, symbols, or combination thereof.  One of the bottles was labeled "DRILL ONLY " and the other bottle had no markings on it.  The bottles contained chemicals which the employees would use to lubricate the drill bits.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Nimsgern Steel Corp's full OSHA safety record →