MARION, OH ·
OSHA Inspection: OVERHEAD DOOR CORPORATION
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of OVERHEAD DOOR CORPORATION in 1295 E. FAIRGROUND, MARION, OH 43302 (NAICS 332321). OSHA activity number 343788592.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- OVERHEAD DOOR CORPORATION
- Site address
- 1295 E. FAIRGROUND
- City
- MARION
- State
- OH
- ZIP
- 43302
- Mailing
- 1332 E. FAIRGROUND RD., MARION, OH 43302
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Union (A)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332321
- Employees
- 60
- Ownership type
- Private (A)
Citations
4 citations on file for this inspection.
1910.147 C06 I
- Issued
- Apr 24, 2019
- Abate by
- May 7, 2019
- Penalty
- Initial $8,525 · Current $5,115 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed: a. On or February 14, 2019, a periodic inspection of the energy control procedures was not performed to ensure that lockout/tagout procedure and requirements of 29 CFR 1910.147 were being followed. The employer did not assure that the energy control procedure for the TD-95 router was inspected.
Recent events (2)
- · I (S) $5115
- · Z (S) $8525
1910.147 C07 I
- Issued
- Apr 24, 2019
- Abate by
- May 7, 2019
- Penalty
- Initial $8,525 · Current $8,525
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that employees acquired the knowledge and skills required for the safe application, usage and removal of energy control devices: a. On or February 14, 2019, the employer did not ensure that employees who setup the TD-95 router were trained in the skills required for the safe application, usage, and removal of energy controls. Employees that setup the machine's stop-blocks and changed cutting bits were not trained to isolate and/or render energy sources safe.
Recent events (2)
- · I (S) $8525
- · Z (S) $8525
1910.147 D
- Issued
- Apr 24, 2019
- Abate by
- May 3, 2019
- Penalty
- Initial $8,525 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): a. On or February 14, 2019, employees were exposed to pinch point and rotating part hazards in that the TD-95 panel router machine was not locked out prior to machine setup tasks. The employer did not ensure that energy control application steps were implemented to control the machine's pneumatic and electrical/mechanical energy sources prior to the servicing tasks; the employer did not: - Ensure employees had the method or means to control hazardous energy. - Affix lockout device(s) to control the energy source(s). - Verify that isolation and de-energization of the machine or equipment had been accomplished.
Recent events (2)
- · I (S) $0
- · Z (S) $8525
1910.212 A01
- Issued
- Apr 24, 2019
- Abate by
- May 3, 2019
- Penalty
- Initial $11,934 · Current $7,160 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a. On or about February 12, 2019, the employer did not ensure that employees were protected from pinch point hazards when the #2 pneumatic foam impactor closed. An employee sustained finger amputation injuries when caught between a platen of the impactor and a platen spacer. b. On or about February 12, 2019, the employer did not ensure that employees were protected from pinch point hazards created when the #1 pneumatic foam impactor closed. Employees were exposed to the pinch point created between the machine's platen and spacer. c. On or about February 11, 2019, the employer did not ensure that rotating bits located on the TD-95 router and drill machine were guarded to protect employees against rotating part hazards. Employees that operated the equipment were exposed to amputation and laceration injuries from the unguarded rotating parts.
Recent events (2)
- · I (S) $7160
- · Z (S) $11934
More inspections at Overhead Door Corporation
View Overhead Door Corporation's full OSHA safety record →
More inspections in this industry (NAICS 332321)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 343788592.