CLEVELAND, OH —
OSHA Inspection: OHIO BLOW PIPE COMPANY
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of OHIO BLOW PIPE COMPANY in 446 E. 131ST STREET, CLEVELAND, OH 44108 (NAICS 333922). OSHA activity number 343815882.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- OHIO BLOW PIPE COMPANY
- Site address
- 446 E. 131ST STREET
- City
- CLEVELAND
- State
- OH
- ZIP
- 44108
- Mailing
- 446 E. 131ST STREET, CLEVELAND, OH 44108
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333922
- Employees
- 52
- Ownership type
- A
Citations
19 citations on file for this inspection.
1910.95 D01
- Issued
- Apr 25, 2019
- Abate by
- Jun 30, 2019
- Penalty
- Initial $6,630 · Current $6,630
General-duty citation text
29 CFR 1910.95(d)(1): When information indicated that any employee's exposure equaled or exceed the 8-hour time-weighted average of 85 decibels, the employer did not develop and implement a monitoring program: a) On February 28, 2019, the fabricator on the Pipe Line in Building 1 was exposed to continuous noise levels at 236.0% of the permissible daily exposure (8-hour, time-weighted average sound level of 85 dbA or equivalently, a dose of 50 percent), during the 422 minute sampling period. Exposure calculations include a zero increment for the 58 minutes not sampled. The employer had not developed or implemented a monitoring program to assess employee noise level exposures in the area. b) On February 28, 2019, the fabricator in Building 2 was exposed to continuous noise levels at 105.6% of the permissible daily exposure (8-hour, time-weighted average sound level of 85 dbA or equivalently, a dose of 50 percent), during the 480 minute sampling period. The employer had not developed or implemented a monitoring program to assess employee noise level exposures in the area.
Recent events (2)
- — I (S) $6630
- — Z (S) $6630
1910.95 G05 II
- Issued
- Apr 25, 2019
- Abate by
- Jun 30, 2019
- Penalty
- Initial $6,630 · Current $0 Reduced
General-duty citation text
29 CFR 1910.95(g)(5)(ii): Where mobile test vans were used to meet the audiometric testing obligation, the employer did not obtain a valid baseline audiogram within 1 year of an employee's first exposure at or above the action level and where baseline audiograms were obtained more than 6 months after the employee's first exposure at or above the action level, employees did not wear hearing protectors for any period exceeding six months after first exposure until the baseline audiogram was obtained: On February 28, 2019, the fabricator in Building 2 was exposed to continuous noise levels at 105.6% of the permissible daily exposure (8-hour, time-weighted average sound level of 85 dBA or equivalently, a dose of 50 percent), during the 480 minute sampling period. The employer failed to establish valid baseline audiograms for employees exposed to the action level in building 2.
Recent events (2)
- — I (S) $0
- — Z (S) $6630
1910.95 G06
- Issued
- Apr 25, 2019
- Abate by
- Jun 30, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.95(g)(6): At least annually after obtaining the baseline audiogram, the employer did not obtain a new audiogram for each employee exposed at or above an 8-hour time-weighted average of 85 decibels: a) On February 28, 2019, the fabricator on the Pipe Line in Building 1 was exposed to continuous noise levels at 236.0% of the permissible daily exposure (8-hour, time-weighted average sound level of 85 dbA or equivalently, a dose of 50 percent), during the 422 minute sampling period. Exposure calculations include a zero increment for the 58 minutes not sampled. The employer failed to obtain annual audiograms for employees exposed to the action level in building 1. b) On February 28, 2019, the fabricator in Building 2 was exposed to continuous noise levels at 105.6% of the permissible daily exposure (8-hour, time-weighted average sound level of 85 dbA or equivalently, a dose of 50 percent), during the 480 minute sampling period. The employer had not developed or implemented a monitoring program to assess employee noise level exposures in the area. The employer failed to obtain annual audiograms for employees exposed to the action level in building 2.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.95 K01
- Issued
- Apr 25, 2019
- Abate by
- May 30, 2019
- Penalty
- Initial $6,630 · Current $4,901 Reduced
General-duty citation text
29 CFR 1910.95(k)(1): The employer did not train each employee who is exposed to noise at or above an 8-hour time-weighted average of 85 decibels in accordance with the requirements of 29 CFR 1910.95(k). The employer did not institute a training program and ensure employee participation in the program: On or about February 28, 2019, the employer failed to provide initial training to employees involved in the hearing conservation program.
Recent events (2)
- — I (S) $4901
- — Z (S) $6630
1910.107 B05 I
- Issued
- Apr 25, 2019
- Abate by
- Jun 30, 2019
- Penalty
- Initial $7,956 · Current $3,978 Reduced
General-duty citation text
29 CFR 1910.107(b)(5)(i): There were no visible gauge(s), audible alarm(s) or pressure activated device(s) installed on paint spray booth(s) to indicate or insure that the required air velocity was maintained: On or about February 28, 2019, the employer did not have the visible gauge on the spray booth to indicate the required air velocity.
Recent events (2)
- — I (S) $3978
- — Z (S) $7956
1910.107 B05 IV
- Issued
- Apr 25, 2019
- Abate by
- Jun 30, 2019
- Penalty
- Initial $7,956 · Current $3,978 Reduced
General-duty citation text
29 CFR 1910.107(b)(5)(iv): Space within the spray booth on the downstream and upstream sides of filters were not protected with approved automatic sprinklers: On or about February 28, 2019, the paint booth located in the spray area did not have a sprinkler system.
Recent events (2)
- — I (S) $3978
- — Z (S) $7956
1910.107 C06
- Issued
- Apr 25, 2019
- Abate by
- May 30, 2019
- Penalty
- Initial $7,956 · Current $0 Reduced
General-duty citation text
29 CFR 1910.107(c)(6): Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined were not explosion-proof type approved for Class I, group D locations and did not otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations: On or about February 28, 2019, the employer installed electrical lighting in the paint spray booth that was not approved for Class I, group D locations. The lighting had residue build up that was found to be ignitable/combustible.
Recent events (2)
- — I (S) $0
- — Z (S) $7956
1910.107 E02
- Issued
- Apr 25, 2019
- Abate by
- May 30, 2019
- Penalty
- Initial $7,956 · Current $3,978 Reduced
General-duty citation text
29 CFR 1910.107(e)(2): The quantity of flammable liquids or liquids with a flashpoint greater than 199.4 degrees F (93 degrees C) kept in the vicinity of spraying operations were not a minimum required for operations or they exceeded a supply for one day or one shift: On or about February 28, 2019, flammable liquids including but not limited to, KEM Aqua 8710 used in spraying operations are stored in the vicinity of the spray booth. More than one day's worth was stored.
Recent events (2)
- — I (S) $3978
- — Z (S) $7956
1910.107 G02
- Issued
- Apr 25, 2019
- Abate by
- May 15, 2019
- Penalty
- Initial $5,304 · Current $2,652 Reduced
General-duty citation text
29 CFR 1910.107(g)(2): All spraying areas were not kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary. Scrapers, spuds, or other such tools used for cleaning purposes shall be of nonsparking material: On or about February 28, 2018, the spray booth had excessive accumulation of combustible residues created by spray operations.
Recent events (2)
- — I (S) $2652
- — Z (S) $5304
1910.133 A05
- Issued
- Apr 25, 2019
- Abate by
- May 30, 2019
- Penalty
- Initial $9,282 · Current $4,641 Reduced
General-duty citation text
29 CFR 1910.133(a)(5): The employer did not ensure that each affected employee used equipment with filter lenses that had a shade number appropriate for the work being performed for protection from injurious light radiation: On or about February 28, 2019, the employer did not ensure employees engaged in welding activities used equipment with filter lenses to protect the eyes from light radiation.
Recent events (2)
- — I (S) $4641
- — Z (S) $9282
1910.134 E01
- Issued
- Apr 25, 2019
- Abate by
- May 15, 2019
- Penalty
- Initial $3,978 · Current $3,978
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: On or about February 18, 2019, the employer failed to provide a medical evaluation to employees who wear half face respirators and dust masks while spray finishing, welding, and grinding.
Recent events (2)
- — I (S) $3978
- — Z (S) $3978
1910.134 K06
- Issued
- Apr 25, 2019
- Abate by
- May 15, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(k)(6): The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer: On or about February 28, 2019, the employer failed to provide respiratory protection training to employees that voluntarily wear respirators including, but not limited to, half face respirators and dust masks.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.307 C
- Issued
- Apr 25, 2019
- Abate by
- May 15, 2019
- Penalty
- Initial $5,304 · Current $2,652 Reduced
General-duty citation text
29 CFR 1910.307(c): Equipment, wiring methods, and installations of equipment in hazardous (classified) locations were not intrinsically safe, approved for the hazardous (classified) location, or safe for the hazardous (classified) location: On or about February 28, 2019, electrical equipment used in the spray booth including, but not limited to, Dayton Wet/Dry Vacuum model 2RPD8, was used in a Class II, Division 1 location, and were not intrinsically safe, approved for a Class II, Division I, location, or safe for a Class II, Division I, location.
Recent events (2)
- — I (S) $2652
- — Z (S) $5304
1910.1200 G08
- Issued
- Apr 25, 2019
- Penalty
- Initial $5,304 · Current $2,652 Reduced
General-duty citation text
29 CFR 1910.1200(g)(8): The employer did not maintain in the workplace copies of the required safety data sheets (SDSs)for each hazardous chemical, and did not ensure that they were readily accessible during each work shift to employees when they were in their work area(s): On or about February 28, 2019, the employer did not maintain SDSs for employees. Employees work with chemicals such as, but not limited to, DTM Acrylic Coating Ultradeep Base, KEM AQUA 8710 Reducible Enamel SW4027 Galvano, and KEM AQUA 8710 Reducible Enamel SW4086.
Recent events (2)
- — I (S) $2652
- — Z (S) $5304
1910.1200 H01
- Issued
- Apr 25, 2019
- Abate by
- May 15, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: On or about February 28, 2019, the employer did not provide hazard communication training to employees. Employees work with chemicals such as, but not limited to, ColorWorks, Anti-Spatter spray, KDTM Acrylic Coating Ultradeep Base, and KEM AQUA 8710 Reducible Enamel.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.107 G07
- Issued
- Apr 25, 2019
- Abate by
- May 15, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(g)(7): "No smoking" signs in large letters on contrasting color background were not posted at all spraying areas and paint storage rooms: On or about February 28, 2019, the employer did not have "no smoking" signs posted on the spray booth located in building 1.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.132 D02
- Issued
- Apr 25, 2019
- Abate by
- May 15, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.132(d)(2): The employer did not verify, through a written certification, the identity of the workplace evaluated, the person certifying that the evaluation had been performed, and the date the hazard assessment was done: On or about February 28, 2019, the workplace hazard assessment had not been put in writing and certified with the person conducting the evaluation and the dates the hazard assessment was completed.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.132 F01
- Issued
- Apr 25, 2019
- Abate by
- May 15, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.132(f)(1): The employer did not provide training to each employee who is required by this section to use personal protective equipment (PPE): On or about February 28, 2019, the employer failed to provide PPE training to employees. Employees are provided PPE including, but not limited to, safety glasses, hearing protection, welding helmets, respirators, fire resistant clothing and gloves.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.157 E02
- Issued
- Apr 25, 2019
- Abate by
- May 15, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly: On or about February 18, 2019, the employer did not visually inspect fire extinguishers in the production area at least monthly.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Ohio Blow Pipe Company
View Ohio Blow Pipe Company's full OSHA safety record →
More inspections in this industry (NAICS 333922)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343815882.