Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: OHIO BLOW PIPE COMPANY

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of OHIO BLOW PIPE COMPANY in 446 EAST 131ST STREET, CLEVELAND, OH 44108 (NAICS 333413). OSHA activity number 347259756.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Ohio Blow Pipe Company — free Get an email when a new federal OSHA severe-injury report for Ohio Blow Pipe Company is published. One employer, no account, unsubscribe in one click.
Site address
446 EAST 131ST STREET
City
CLEVELAND
State
OH
ZIP
44108
Mailing
446 EAST 131ST STREET ATTN: RICK TIMM, CLEVELAND, OH 44108
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333413
Employees
60
Ownership type
A

3 citations on file for this inspection.

1910.212 A01

Serious Gravity 1 1 instance 2 exposed
Issued
Jun 3, 2024
Penalty
Initial $4,113 · Current $4,113
29 CFR  1910.212(a)(1):Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices,electronic safety devices, etc.  On or about February 6, 2024, the employer did not ensure that the rotating drill bit on the Barnes Drill Company drill press, located in building #2/main building, was provided with a shield guard to prevent employee exposure to flying chips and point of operation hazard.
Recent events (1)
  • — Z (S) $4113

1910.179 L03 III C

Other-than-serious 1 instance 2 exposed
Issued
Jun 3, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.179(l)(3)(iii)(c): All critical parts which are cracked, broken, bent, or excessively worn.   On or about February 6, 2024, the employer did not ensure that the Campbell 1/2 ton GX plate clamp used to pick up sheets of metal to be welded, located in building #1/middle building, was taken out of service and  replaced when found to have a bent eye bolt.
Recent events (1)
  • — Z (O) $0

1910.179 G01 V

Other-than-serious 1 instance 2 exposed
Issued
Jun 3, 2024
Penalty
Initial $0 · Current $0
29 CFR  1910.179(g)(1)(v):Pendant control box(es) were not clearly marked for identification of functions:  On or about February 6, 2024, the employer did not ensure employees utilizing the two ton crane, located in building #1/middle building, had a pendent that had the up and down buttons clearly marked. The up and down indicators were worn off.
Recent events (1)
  • — Z (O) $0

View Ohio Blow Pipe Company's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347259756.