LOLETA, CA —
OSHA Inspection: BEAR RIVER CASINO HOTEL
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of BEAR RIVER CASINO HOTEL in 11 BEAR PAWS WAY, LOLETA, CA 95551 (NAICS 721120). OSHA activity number 343875746.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BEAR RIVER CASINO HOTEL
- Site address
- 11 BEAR PAWS WAY
- City
- LOLETA
- State
- CA
- ZIP
- 95551
- Mailing
- 11 BEAR PAWS WAY, LOLETA, CA 95551
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 721120
- Employees
- 400
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.28 B01 I
- Issued
- May 1, 2019
- Abate by
- May 24, 2019
- Penalty
- Initial $6,440 · Current $4,830 Reduced
General-duty citation text
29 CFR 1910.28(b)(1)(i): The employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2 m) or more above a lower level was protected from falling: Storage Bldg., Mezzanine: A 9 ft. high platform was accessed by employees to store various bulk items and the inadequately constructed guardrails did not protect employees from fall hazards for the following reasons; a. An approximately 3 ft. section of standard guardrails was missing from the left side of the mezzanine. b. The front length of the storage mezzanine was missing mid-rails.
Recent events (2)
- — I (S) $4830
- — Z (S) $6440
1910.29 K01
- Issued
- May 1, 2019
- Abate by
- May 24, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.29(k)(1): (k) The employer must ensure toeboards used for falling object protection. Storage Bldg., Mezzanine: A 9 ft. high platform is accessed by employees to store various bulk items. Toeboards were not integrated into the guardrail system. Toeboards should have a minimum vertical height of 3.5" from the level of the walking-working surface to the top edge of the toeboards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C01
- Issued
- May 1, 2019
- Abate by
- May 24, 2019
- Penalty
- Initial $6,440 · Current $4,830 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: Maintenance: Employees performing electrical repairs and maintenance on HVAC systems are exposed to hazards associated with the accidental release of stored energy types such as electrical and mechanical (belts, pulleys, fan blades). Although a process is followed, procedures are not in writing and do not encompass the requirements of this section.
Recent events (2)
- — I (S) $4830
- — Z (S) $6440
1910.147 C07 I A
- Issued
- May 1, 2019
- Abate by
- May 24, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolate Maintenance: Authorized employees that maintain HVAC systems and perform electrical repairs are exposed to the unexpected release of stored energy types such as electrical and mechanical (belts, pulleys, fan blades). They have not received the required lock-out/tag-out training.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.22 B
- Issued
- May 1, 2019
- Abate by
- May 24, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.22(b): For every walking and working surface used for storage, the employer had not ensured that the employee knew of the maximum intended load. Upper Storage Bldg., Mezzanine: A 9 ft. high platform is accessed by employees to store various bulk items. The maximum allowable weight load has not been determined.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.132 D01
- Issued
- May 1, 2019
- Abate by
- May 24, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.132(d)(1): The employer did not assess the workplace determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE): Casino/hotel: The employer did not assess the workplace to determine if employees, particularly maintenance workers, are required to wear personal protective equipment such as ear plugs or muffs to protect against excessive noise, eye protection when performing maintenance and grounds keeping duties. or the use of gloves when using chemical products such as paint. The assessment needs to be written, signed, and dated by the assessor.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Bear River Casino Hotel
View Bear River Casino Hotel's full OSHA safety record →
More inspections in this industry (NAICS 721120)
More inspections in CA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343875746.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.