DELAWARE CITY, DE —
OSHA Inspection: DELAWARE CITY REFINING COMPANY, LLC
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of DELAWARE CITY REFINING COMPANY, LLC in 4550 WRANGLE HILL ROAD, DELAWARE CITY, DE 19706 (NAICS 324110). OSHA activity number 343923074.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DELAWARE CITY REFINING COMPANY, LLC
- Site address
- 4550 WRANGLE HILL ROAD
- City
- DELAWARE CITY
- State
- DE
- ZIP
- 19706
- Mailing
- 4550 WRANGLE HILL ROAD, DELAWARE CITY, DE 19706
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 324110
- Employees
- 600
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.119 J02
- Issued
- Oct 9, 2019
- Abate by
- Nov 5, 2019
- Penalty
- Initial $10,419 · Current $0 Reduced
General-duty citation text
29 CFR 1910.119(j)(2): Inspection and testing procedures did not follow recognized and generally accepted good engineering practices (RAGAGEP): a) Delaware City Refining Company, 4550 Wrangle Hill Road, Delaware City, Delaware; Fluid Coker Reactor - On or about April 9, 2019, the employer failed to follow RAGAGEP for the postweld heat treatment of a replaced section of the Coker Shell, exposing employees to a fire hazard. Abatement Note: Both the American Petroleum Institute's API 510, Pressure Vessel Inspection Code: In-Service Inspection, Rating, Repair, and Alteration and American Society of Mechanical Engineers' PCC-2, Repair of Pressure Equipment and Piping, Article 2.14, provide guidance for post weld heat treatment as does the National Fire Protection Association's NFPA® 51B Standard for Fire Prevention During Welding, Cutting, and Other Hot Work.
Recent events (3)
- — F (S) $0
- — C (S) $10419
- — Z (S) $10419
1910.252 A01 I
- Issued
- Oct 9, 2019
- Abate by
- Nov 5, 2019
- Penalty
- Initial $10,419 · Current $0 Reduced
General-duty citation text
29 CFR 1910.252(a)(1)(i): When the object to be welded or cut could not be readily moved, all movable fire hazards in the vicinity were not taken to a safe place: a) Delaware City Refining Company, 4550 Wrangle Hill Road, Delaware City, Delaware; Fluid Coker Reactor - On or about April 9, 2019, the employer failed to remove all combustible materials (e.g.; temporary wood decking inside the Coker Shell) or properly shield against ignition of temporary wood decking inside the Coker Shell during postweld heat treatment of a replaced section of the Coker Shell, exposing employees to a fire hazard.
Recent events (3)
- — F (S) $0
- — C (S) $10419
- — Z (S) $10419
1910.252 A02 XIV C 2
- Issued
- Oct 9, 2019
- Abate by
- Jul 15, 2020
- Penalty
- Initial $0 · Current $50,000
General-duty citation text
29 CFR 1910.252(a)(2)(xiv)(C)(2): The employer did not ensure that if the work could not be moved, the supervisor had the combustibles moved to a safe distance from the work or had the combustibles properly shielded against ignition: a) Delaware City Refining Company, 4550 Wrangle Hill Road, Delaware City, Delaware; Fluid Coker Reactor - On or about April 9, 2019, the employer failed to move all combustible materials (e.g., temporary wood decking) to a safe distance from the post weld heat treatment work inside Coker unit, or have the combustibles properly shielded against ignition during post weld heat treatment of a replaced section of the Coker Shell, exposing employees to a fire hazard.
Recent events (3)
- — F (O) $50000
- — C (S) $0
- — Z (S) $0
1910.119 F04
- Issued
- Oct 9, 2019
- Abate by
- Nov 27, 2019
- Penalty
- Initial $52,096 · Current $0 Reduced
General-duty citation text
29 CFR 1910.119(f)(4): The employer did not develop and implement safe work practices to provide for the control of hazards during operations: a) Delaware City Refining Company, 4550 Wrangle Hill Road, Delaware City, Delaware; Fluid Coker Reactor - On or about April 9, 2019, the employer failed to develop and implement safe work practices for the control of hot work hazards during the post weld heat treatment of a replaced section of the Coker Shell, exposing employees to a fire hazard. The Delaware City Refining Company, LLC was previously cited for a violation of this occupational safety and health standard, 29 CFR 1910.119(f)(4), which was contained in OSHA inspection number 1108618, citation number 1, item number 1, and was affirmed as a final order on 12/21/2016, with respect to a workplace located at 4550 Wrangle Hill Road, Delaware City, DE 19706.
Recent events (3)
- — F (R) $0
- — C (R) $52096
- — Z (R) $52096
More inspections at Delaware City Refining Company, LLC
View Delaware City Refining Company, LLC's full OSHA safety record →
More inspections in this industry (NAICS 324110)
More inspections in DE
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 343923074.