OSHA Inspection: FIREPLACE AND CHIMNEY AUTHORITY, INC.

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of FIREPLACE AND CHIMNEY AUTHORITY, INC. in 1615 MILLVIEW DRIVE, BATAVIA, IL 60510 (NAICS 238140). OSHA activity number 343995411.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Fireplace and Chimney Authority, INC. — free Get an email when a new federal OSHA severe-injury report for Fireplace and Chimney Authority, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1615 MILLVIEW DRIVE
City
BATAVIA
State
IL
ZIP
60510
Mailing
120 E. LAKE ST., ELMHURST, IL 60126
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
30
Ownership type
A

3 citations on file for this inspection.

1926.501 B13

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 13, 2019
Abate by
Oct 7, 2019
Penalty
Initial $6,630 · Current $3,750 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b):     On 09 May 2019, at a worksite located at 1615 Millview Drive, Batavia IL 60510, employees who were removing and replacing a chimney cap on the roof of a residential structure were exposed to fall hazards of approximately 9 feet.  No form of fall protection was being utilized during this work activity.    Abatement documentation is required for this item in accordance with 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $3750
  • — Z (S) $6630

1926.503 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 13, 2019
Abate by
Oct 7, 2019
Penalty
Initial $6,630 · Current $3,750 Reduced
29 CFR 1926.503(a)(1): The employer shall provide a training program for each employee who might be exposed to fall hazards. The program shall enable each employee to recognize the hazards of falling and shall train each employee in the procedures to be followed in order to minimize these hazards.    On 09 May 2019, at a worksite located at 1615 Millview Drive, Batavia IL 60510, employees who were removing and replacing a chimney cap on the roof of a residential structure were not trained adequately to recognize the hazards of falling and the steps to mitigate those hazards.  No form of fall protection was being utilized during this work activity, exposing employees to falls of approximately 9 feet.    Abatement documentation is required for this item in accordance with 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $3750
  • — Z (S) $6630

1926.1053 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 13, 2019
Abate by
Oct 7, 2019
Penalty
Initial $5,304 · Current $3,000 Reduced
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:    On 09 May 2019, at a worksite located at 1615 Millview Drive, Batavia IL 60510, employees of FIREPLACE AND CHIMNEY AUTHORITY, INC, who were engaged in residential construction operations were using a metal extension ladder that was not extended to at least three feet above the eave to allow for safe access to the roof. This exposed employees to a fall of approximately 9 feet onto concrete below.     Abatement certification is required for this item in accordance with 29 CFR 1903.19(c).
Recent events (2)
  • — I (S) $3000
  • — Z (S) $5304

View Fireplace and Chimney Authority, INC.'s full OSHA safety record →