FORT WORTH, TX —
OSHA Inspection: LEGACY HOUSING CORPORATION
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of LEGACY HOUSING CORPORATION in 4801 MARK IV PARKWAY, FORT WORTH, TX 76106 (NAICS 321991). OSHA activity number 344073200.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- LEGACY HOUSING CORPORATION
- Site address
- 4801 MARK IV PARKWAY
- City
- FORT WORTH
- State
- TX
- ZIP
- 76106
- Mailing
- 4801 MARK IV PARKWAY, FORT WORTH, TX 76106
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321991
- Employees
- 220
- Ownership type
- A
Citations
11 citations on file for this inspection.
1910.28 B01 I
- Issued
- Sep 27, 2019
- Penalty
- Initial $8,856 · Current $4,200 Reduced
General-duty citation text
29 CFR 1910.28(b)(1)(i): The employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that was 4 feet (1.2 m) or more above a lower level was protected from falling by one or more of the following: Guardrail systems, safety net systems, or personal fall arrest systems: On or about June 11, 2019; and at times prior thereto; in the floor production area, the employer did not ensure working platforms were equipped with guard rails exposing employees to fall hazards of (4) feet or greater to the ground below.
Recent events (2)
- — I (S) $4200
- — Z (S) $8856
1910.157 C01
- Issued
- Sep 27, 2019
- Penalty
- Initial $5,314 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: On or about June 11, 2019; and at times prior thereto; in the production area, the employer did not ensure fire extinguishers were mounted and identified, employees were potentially exposed to burn injuries. 1. Identified fire extinguisher location near the floor department exit was not equipped with a fire extinguisher. 2. Identified fire extinguisher location near the floor department, bay door was not was not equipped with a fire extinguisher. 3. Identified fire extinguisher location near the sheet rock and wall bay door was not equipped with a fire extinguisher. 4. Identified fire extinguisher location pole near the employee break sheet rock and wall bay was not equipped with a fire extinguisher.
Recent events (2)
- — I (S) $2000
- — Z (S) $5314
1910.157 E01
- Issued
- Sep 27, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(e)(1): The employer shall be responsible for the inspection, maintenance and testing of all portable fire extinguishers in the workplace: On or about June 11, 2019; and at times prior thereto; in the production areas, the employer did not ensure mounted fire extinguishers were inspected monthly, employees were potentially exposed to burn injuries. 1. Fire extinguisher located in the employee break area near the exit door was not inspected. 2. Fire extinguisher located at the cabinet and floor area exit was not inspected since 2017. 3. Fire extinguisher located near the sheet rock and wall area was not inspected and had been used.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.176 B
- Issued
- Sep 27, 2019
- Penalty
- Initial $7,084 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.176(b): Material stored in tiers was not stacked, blocked, interlocked or limited in height so that it was stable and secure against sliding and collapse: On or about June 11, 2019; and at times prior thereto; in the floor and plumbing production area, employees used wooden warehouse storage racks that had damaged horizontal components. Employees were exposed to falling objects and struck-by hazards created by potential structural failure and collapse of storage rack systems.
Recent events (2)
- — I (S) $3000
- — Z (S) $7084
1910.176 C
- Issued
- Sep 27, 2019
- Penalty
- Initial $5,314 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.176(c): Storage areas were not kept free from accumulation of materials that constituted hazards from tripping, fire, explosion or pest harborage: On or about June 11, 2019; and at times prior thereto; at the maintenance department yard area and outside storage areas, the employer did not ensure storage areas were kept free of accumulation of flammable materials exposing employees to fire hazards.
Recent events (2)
- — I (S) $2000
- — Z (S) $5314
1910.178 P01
- Issued
- Sep 27, 2019
- Penalty
- Initial $7,084 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s): On or about June 11, 2019; and at times prior thereto; in the yard production area, the employer did not ensure the Ingersoll Rand T7008G Tow Tractor operated in a safe condition. The front left tire was missing a large piece of the tire.
Recent events (2)
- — I (S) $3000
- — Z (S) $7084
1910.212 A05
- Issued
- Sep 27, 2019
- Penalty
- Initial $8,856 · Current $4,000 Reduced
General-duty citation text
29 CFR 1910.212(a)(5): Fan blade guard(s) were not provided where the periphery of the blades was less than seven feet from the floor or working level: On or about June 11, 2019; and at times prior thereto; in the cabinet production area, employees used a portable shop fan with the center section of the guard missing exposing the rotating metal blades of the fan. Employees were exposed to laceration and/or amputation hazards.
Recent events (2)
- — I (S) $4000
- — Z (S) $8856
1910.219 F03
- Issued
- Sep 27, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven -7 feet or less above floors, or platforms were not enclosed: On or about June 11, 2019; and at times prior thereto; in the floor and plumbing production area, the employer did not ensure the Floor Decking Trolley chain and sprockets were guarded.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 B01
- Issued
- Sep 27, 2019
- Penalty
- Initial $5,314 · Current $1,800 Reduced
General-duty citation text
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees: On or about June 11, 2019; and at times prior thereto; the employer did not ensure electrical equipment was free of hazards exposing the employees to potential electrical shock or fire hazards. 1. In the cabinet production area, employees used a shop floor fan with flexible extension cord that had the internal wires pulled out plugged into a damaged outlet. 2. In the wall production area, employees used damaged florescent lighting fixtures that were not equipped with a cover.
Recent events (2)
- — I (S) $1800
- — Z (S) $5314
1910.303 G01 II
- Issued
- Sep 27, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1)(ii): Working space for equipment likely to require examination, adjustment, servicing, or maintenance while energized was used for storage: On or about June 11, 2019; and at times prior thereto; in the cabinet production area, electrical disconnects and circuit breaker panels were blocked by equipment exposing employees to hazards in the event of an emergency requiring electrical power to be disconnected.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 G02 III
- Issued
- Sep 27, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws: On or about June 11, 2019; and at times prior thereto; the employer did not ensure electrical equipment was provided with strain relief, exposing the employees to electrical shock and fire hazards. 1. In cabinet production area, a shop floor fan was not provided with strain relief. 2. In the floor production area, the floor decking trolley flexible cord was not provided with strain relief.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Legacy Housing Corporation
View Legacy Housing Corporation's full OSHA safety record →
More inspections in this industry (NAICS 321991)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344073200.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.