FORT WORTH, TX —
OSHA Inspection: LEGACY HOUSING CORPORATION
Follow-up inspection · Health discipline
At a glance
On , OSHA opened a follow-up health inspection of LEGACY HOUSING CORPORATION in 4801 MARK IV PARKWAY, FORT WORTH, TX 76106 (NAICS 321991). OSHA activity number 348331828.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- LEGACY HOUSING CORPORATION
- Site address
- 4801 MARK IV PARKWAY
- City
- FORT WORTH
- State
- TX
- ZIP
- 76106
- Mailing
- 4801 MARK IV PARKWAY, FORT WORTH, TX 76106
What kind of inspection was it?
- Inspection type
- Follow-up (F)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321991
- Employees
- 158
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.95 G05 II
- Issued
- Dec 19, 2025
- Penalty
- Initial $14,188 · Current $14,188
81108111
General-duty citation text
29 CFR 1910.95(g)(5)(ii): Where mobile test vans were used to meet the audiometric testing obligation, the employer did not obtain a valid baseline audiogram within 1 year of an employee's first exposure at or above the action level: On or about June 25, 2025, and at times prior thereto and thereafter, baseline audiograms were not obtained within one year for employees exposed to noise level exceeding the action levels in the following instances (a-b): a. In the Floor Production area, baseline audiogram was not obtained for an employee exposed to the permissible exposure level (PEL) of 93 decibels, equivalent to 155% of the allowable 100% dose for an 8-hour time-weighted average (TWA). The exposure was derived from a sample collected over 432 minutes. This employee was originally exposed to PEL of 91 decibels, equivalent to 141% of the allowable 100% dose for an 8-hour TWA on or about February 23, 2024; and b. In the Shingles Production area, baseline audiogram was not obtained for employee exposed to the action level (AL) of 88 decibels, equivalent to 80% of the allowable 50% dose for an 8-hour time-weighted average (TWA). The exposure was derived from a sample collected over 417 minutes. This employee was originally exposed to AL of 87 decibels, equivalent to 90% of the allowable 50% dose for an 8-hour TWA on or about February 23, 2024.
Recent events (2)
- — C (S) $14188
- — Z (S) $14188
1910.95 C01
- Issued
- Dec 19, 2025
- Abate by
- Feb 11, 2026
- Penalty
- Initial $14,184 · Current $14,184
81108111
General-duty citation text
29 CFR 1910.95(c)(1): The employer did not administer a continuing, effective hearing conservation program as described in in paragraphs (c) through (o), whenever employee noise exposures equal or exceed an 8-hour time-weighted average sound level (TWA) of 85 decibels measured on the A scale, or equivalently a dose of fifty percent: On or about June 25, 2025, and at times prior thereto and thereafter, a written hearing conservation program was not developed and effectively implemented when employees were exposed to hazardous noise levels in the following instances (a-d): a. In the floor production area, an employee was exposed to noise levels exceeding the permissible exposure level (PEL) of 93 decibels, equivalent to 155% of the allowable 100% dose for an 8-hour time-weighted average (TWA). The exposure was derived from a sample collected over 432 minutes; b. In the Shingles Production area an employee was exposed to noise levels exceeding the action level (AL) of 88 decibels, equivalent to 80% of the allowable 50% dose for an 8-hour time-weighted average (TWA). The exposure was derived from a sample collected over 417 minutes; c. In the Roof/Exterior Production area, an employee was exposed to noise levels exceeding the action level (AL) of 88 decibels, equivalent to 75% of the allowable 50% dose for an 8-hour time-weighted average (TWA). The exposure was derived from a sample collected over 417 minutes; and d. In the Side Wall Production area an employee was exposed to noise levels exceeding the action level (AL) of 88 decibels, equivalent to 71% of the allowable 50% dose for an 8-hour time-weighted average (TWA). The exposure was derived from a sample collected over 413 minutes. Legacy Housing Corporation was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.95(c)(1), which was contained in OSHA inspection number 1722985, Citation Number 1, Item number 1, and was affirmed as a final order on November 18, 2024, with respect to a workplace located at 4801 Mark IV Parkway, Fort Worth, TX 76106.
Recent events (2)
- — C (R) $14184
- — Z (R) $14184
More inspections at Legacy Housing Corporation
View Legacy Housing Corporation's full OSHA safety record →
More inspections in this industry (NAICS 321991)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348331828.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.