OSSEO, WI —
OSHA Inspection: SOURCECUT INDUSTRIES, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of SOURCECUT INDUSTRIES, INC. in 51149 WHITETAIL ROAD, OSSEO, WI 54758 (NAICS 321999). OSHA activity number 344074216.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SOURCECUT INDUSTRIES, INC.
- Site address
- 51149 WHITETAIL ROAD
- City
- OSSEO
- State
- WI
- ZIP
- 54758
- Mailing
- 51149 WHITETAIL ROAD, OSSEO, WI 54758
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321999
- Employees
- 90
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.147 C04 II B
- Issued
- Aug 8, 2019
- Abate by
- Sep 6, 2019
- Penalty
- Initial $10,210 · Current $7,147 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy: (a) Building 1, Moulder W90-LMC-Leadermac Platinum 523; The energy control procedure for the moulder failed to identify the primary energy sources such as the power disconnect, and the subsequent steps for affixing lock(s) at the disconnect location(s), in order to isolate energy at the source. (b) Building 1, Moulder W9-Leadermac-C230-6; The energy control procedure for the moulder failed to identify the primary energy sources such as the power disconnect, and the subsequent steps for affixing lock(s) at the disconnect location(s), in order to isolate energy at the source.
Recent events (2)
- — I (S) $7147
- — Z (S) $10210
1910.147 C07 I A
- Issued
- Aug 8, 2019
- Abate by
- Sep 6, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control: (a) Building 1; Employees were performing authorized lockout/tagout tasks during setup which included, but is not limited to, changing cutting heads and rubber rollers without adequate training.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 D03
- Issued
- Aug 8, 2019
- Abate by
- Sep 6, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s): (a) Building 1, Moulder W90-LMC-Leadermac Platinum 523; On or about May 30, 2019 energy isolation devices were not operated in such a manner as to isolate the moulder at the primary electrical disconnect during setup tasks. (b) Building 1, Moulder W90-LMC-Leadermac Platinum 523; Energy isolation devices were not operated in such a manner as to isolate the moulder at the primary electrical disconnect during setup tasks. (c) Building 1, Moulder W9-Leadermac-C230-6; Energy isolation devices were not operated in such a manner as to isolate the moulder at the primary electrical disconnect during setup tasks.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 D04 I
- Issued
- Aug 8, 2019
- Abate by
- Sep 6, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: (a) Building 1, Moulder W90-LMC-Leadermac Platinum 523; On or about May 30, 2019 lockout or tagout devices were not affixed to each energy isolating device by authorized employee(s) while an employee was working inside of the moulder performing setup tasks. (b) Building 1, Moulder W90-LMC-Leadermac Platinum 523; Lockout or tagout devices were not affixed to each energy isolating device by authorized employee(s) while an employee was working inside of the moulder performing setup tasks. (c) Building 1, Moulder W9-Leadermac-C230-6; Lockout or tagout devices were not affixed to each energy isolating device by authorized employee(s) while an employee was working inside of the moulder performing setup tasks.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C07 I A
- Issued
- Aug 8, 2019
- Abate by
- Sep 6, 2019
- Penalty
- Initial $10,210 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: (a) Building 1; The employer did not conduct an annual audit of the energy control procedures for machinery including, but not limited to, the LMC- Leadermac Platinum 523, Leadermac-C230-6, and the Kentwood M609X to ensure that the procedures met the requirement of the lockout standard and were being adequately followed.
Recent events (2)
- — I (O) $0
- — Z (S) $10210
1910.212 A01
- Issued
- Aug 8, 2019
- Abate by
- Sep 6, 2019
- Penalty
- Initial $10,210 · Current $7,145 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: ((a) Building 1, Moulder W90-LMC-Leadermac Platinum 523; On or about May 30, 2019 the moulder was operated without adequate machine guarding. (b) Building 1, Moulder W9-Leadermac-C230-6; On or about May 30, 2019 2019 the moulder was operated without adequate machine guarding.
Recent events (2)
- — I (S) $7145
- — Z (S) $10210
1910.213 N01
- Issued
- Aug 8, 2019
- Abate by
- Sep 6, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.213(n)(1): Metal guard(s) covering the cutting head(s), and saw(s) if used, were not provided on: (a) Building 1, Moulder W90-LMC-Leadermac Platinum 523; A metal guard was not provided to cover cutting head #1. (b) Building 1, Moulder W9-Leadermac-C230-6; A metal guard was not provided to cover cutting head #1.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Sourcecut Industries, INC.
View Sourcecut Industries, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 321999)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344074216.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.