FORT BELVOIR, VA —
OSHA Inspection: VIRGINIA STEEL ERECTORS INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of VIRGINIA STEEL ERECTORS INC. in GOETHALS ROAD AND BLACK ROAD, FORT BELVOIR, VA 22060 (NAICS 238120). OSHA activity number 344177001.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- VIRGINIA STEEL ERECTORS INC.
- Site address
- GOETHALS ROAD AND BLACK ROAD
- City
- FORT BELVOIR
- State
- VA
- ZIP
- 22060
- Mailing
- 7716 JEFFERSON DAVIS HIGHWAY, RICHMOND, VA 23237
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238120
- Employees
- 11
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.351 B02
- Issued
- Oct 10, 2019
- Penalty
- Initial $3,832 · Current $1,916 Reduced
General-duty citation text
29 CFR 1926.351(b)(2): Welding cable(s) in use were not free from improper repair or splices for a minimum distance of 10 feet from the cable end to which the electrode holder was connected: a) Fort Belvoir: On or about 07/24/2019, an employee used a welding lead to weld angle irons on the exterior of a stair tower that had cuts through the outer jacket at 33 inches and 88 inches from the electrode holder, as a result employee was exposed to a possible shock hazard. No abatement certification or documentation required.
Recent events (2)
- — I (S) $1916
- — Z (S) $3832
1926.404 B01 II
- Issued
- Oct 10, 2019
- Abate by
- Nov 6, 2019
- Penalty
- Initial $3,381 · Current $1,691 Reduced
General-duty citation text
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupers for personal protection: a) Fort Belvoir: On or about 07/24/2019, a Metabo portable grinder powered by a Trailer Blazer 325 diesel, DC welder 12,000 Watt generator was that did not have a ground fault circuit interrupter device as a result an employee was exposed to a possible shock hazard. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $1690.5
- — Z (S) $3381
1926.451 E01
- Issued
- Oct 10, 2019
- Abate by
- Nov 6, 2019
- Penalty
- Initial $4,508 · Current $2,254 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Cross braces were used as a means of access: a) Fort Belvoir: On or about 07/24/2019, employees used an 8ft detached stepladder to access and egress a tubular welded frame scaffold erected approximately 7 feet from the deck, as a result was exposed to a possible fall hazard. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $2254
- — Z (S) $4508
1926.454 A
- Issued
- Oct 10, 2019
- Abate by
- Nov 15, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. a) Fort Belvoir: On or about 07/24/2019, employees working from a tubular welded frame scaffold were not trained in the recognition and avoidance of hazards associated with tubular welded frame scaffold usage. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1053 B01
- Issued
- Oct 10, 2019
- Abate by
- Nov 6, 2019
- Penalty
- Initial $4,508 · Current $2,254 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) Fort Belvoir: On or about 07/24/2019, an employee used an 8ft stepladder to access and egress the upper landing of a tubular welded frame scaffold, as a result was exposed to a possible fall hazard. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $2254
- — Z (S) $4508
1926.403 B02
- Issued
- Oct 10, 2019
- Abate by
- Nov 6, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: a) Fort Belvoir: On or about 07/24/2019, extension cords used to supply power to a grinder were not used in accordance with instructions included in the labeling in that extension cords were plugged one into another. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1926.416 E01
- Issued
- Oct 10, 2019
- Abate by
- Nov 6, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used: a) Fort Belvoir: On or about 07/24/2019, an employee used an electric grinder with a gouge in outer sheathing which exposed the inner insulated wires. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Virginia Steel Erectors INC.
View Virginia Steel Erectors INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238120)
More inspections in VA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344177001.