NORTH REDINGTON BEACH, FL —
OSHA Inspection: ACOMA ROOFING, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ACOMA ROOFING, INC. in 16800 GULF BLVD., NORTH REDINGTON BEACH, FL 33708 (NAICS 238160). OSHA activity number 344198783.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ACOMA ROOFING, INC.
- Site address
- 16800 GULF BLVD.
- City
- NORTH REDINGTON BEACH
- State
- FL
- ZIP
- 33708
- Mailing
- 301 DOUGLAS ROAD EAST, OLDSMAR, FL 34677
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 6
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.501 B11
- Issued
- Dec 23, 2019
- Penalty
- Initial $9,282 · Current $5,569 Reduced
General-duty citation text
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: a) Seascape Condos - Six roofers were shingling 5.5 in 12 pitched roofs that varied from 9 feet 11 inches up to over 22 feet, on or about August 1, 2019.
Recent events (2)
- — I (S) $5569.2
- — Z (S) $9282
1926.1053 B01
- Issued
- Dec 23, 2019
- Penalty
- Initial $7,956 · Current $4,774 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) Seascape Condos - Several extension ladders used on the site extended various lengths, from approximately 6 inches past the roof edge to approximately 18 inches past the roof edge, on or about August 1, 2019.
Recent events (2)
- — I (S) $4773.6
- — Z (S) $7956
1926.1060 A
- Issued
- Dec 23, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1060(a): The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would enable each employee to recognize hazards related to ladders and stairways and train each employee in the procedures to be followed to minimize these hazards: a) Seascape Condos - Training was not provided to employees using extension ladders that extended various lengths, from approximately 6 inches past the roof edge to approximately 18 inches past the roof edge, on or about August 1, 2019.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Acoma Roofing, INC.
View Acoma Roofing, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344198783.