Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: LUXOTTICA GROUP

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of LUXOTTICA GROUP in 101 GREENWOOD INDUSTRIAL PARKWAY, MCDONOUGH, GA 30253 (NAICS 333314). OSHA activity number 344215090.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Luxottica Group — free Get an email when a new federal OSHA severe-injury report for Luxottica Group is published. One employer, no account, unsubscribe in one click.
Establishment
LUXOTTICA GROUP
Site address
101 GREENWOOD INDUSTRIAL PARKWAY
City
MCDONOUGH
State
GA
ZIP
30253
Mailing
100 GREENWOOD INDUSTRIAL PARKWAY, MCDONOUGH, GA 30253
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333314
Employees
1630
Ownership type
A

3 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 10 9 instances 24 exposed
Issued
Jan 10, 2020
Abate by
Feb 6, 2020
Penalty
Initial $13,260 · Current $6,630 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  On or about 8-6-2019, in the RXO lab and Swarf production area at 101 Greenwood Industrial Blvd, McDonough, GA: Employees performing servicing and maintenance activities on the equipment and machines, were exposed to amputation and caught-in hazards, in that; no procedures were developed or utilized to control the electrical, heat, and gravitational energy sources such as but not limited to the following equipment.  a. Employer did not developed procedure - OPTO Tech Taper OTT 80 CAN-A Schneider - Electrical and heat energy sources b. Employer did not developed procedure- Swarf equipment - Electrical, water, and high pressure energy sources c. Employer did not developed procedure- Transfer Pumps and Filter system HSC Lines - Electrical, heat, water pressure energy sources d. Employer did not enforce utilization of procedure -  CCU Modulo Schneider Electrical, pneumatic, water, and heat sources e. Employer did not enforce utilization of procedure -  HSC Modulo XT Schneider Electrical, pneumatic, water, and heat sources f. Employer did not enforce utilization of procedure -  CCP Modulo Schneider Electrical, pneumatic, water, and heat sources g. Employer did not enforce utilization of procedure -  DBA Modulo Schneider Electrical, pneumatic, water, and heat sources h. Employer did not enforce utilization of procedure -  CCL Modulo Schneider Electrical, pneumatic, water, and heat sources i. Employer did not enforce utilization of procedure -  Velocity 1400818 Coburn Tech Electrical, pneumatic, water, and heat sources
Recent events (3)
  • — F (S) $6630
  • — C (S) $13260
  • — Z (S) $13260

1910.147 C06 I

Other-than-serious Gravity 10 9 instances 24 exposed
Issued
Jan 10, 2020
Abate by
Feb 6, 2020
Penalty
Initial $13,260 · Current $6,630 Reduced
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  On or about 8-6-2019, in the RXO lab and Swarf production area at 101 Greenwood Industrial Blvd, McDonough, GA:  Authorized and affected employees performing servicing and maintenance on the equipment and machines not limited to the ones listed below, were exposed to amputation and caught-in hazards.  The last documented periodic inspections modification to meet plant specifics was 4/17/2018.  a. OPTO Tech Taper OTT 80 CAN-A Schneider - Electrical and heat energy sources b. Swarf equipment - Electrical, water, and high pressure energy sources c. Transfer Pumps and Filter system HSC Lines - Electrical, heat, water pressure energy sources d. CCU Modulo Schneider Electrical, pneumatic, water, and heat sources e. HSC Modulo XT Schneider Electrical, pneumatic, water, and heat sources f. CCP Modulo Schneider Electrical, pneumatic, water, and heat sources g. DBA Modulo Schneider Electrical, pneumatic, water, and heat sources h. CCL Modulo Schneider Electrical, pneumatic, water, and heat sources I. Velocity 1400818 Coburn Tech Electrical, pneumatic, water, and heat sources
Recent events (3)
  • — F (O) $6630
  • — C (S) $13260
  • — Z (S) $13260

1910.147 C07 I A

Serious Gravity 10 9 instances 24 exposed
Issued
Jan 10, 2020
Abate by
Feb 6, 2020
Penalty
Initial $13,260 · Current $6,630 Reduced
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control.  On or about 8-6-2019, in the RXO lab and Swarf production area at 101 Greenwood Industrial Blvd, McDonough, GA:  Employees performing servicing and maintenance activities on the equipment and machines, were exposed to amputation and caught-in hazards, in that in that they were not aware of the electrical, heat, mechanical, and gravitational energy sources or how to isolate the sources in equipment such as but not limited to equipment listed below.  a. OPTO Tech Taper OTT 80 CAN-A Schneider - Electrical and heat energy sources b. Swarf equipment - Electrical, water, and high pressure energy sources c. Transfer Pumps and Filter system HSC Lines - Electrical, heat, water pressure energy sources d. CCU Modulo Schneider Electrical, pneumatic, water, and heat sources e. HSC Modulo XT Schneider Electrical, pneumatic, water, and heat sources f. CCP Modulo Schneider Electrical, pneumatic, water, and heat sources g. DBA Modulo Schneider Electrical, pneumatic, water, and heat sources h. CCL Modulo Schneider Electrical, pneumatic, water, and heat sources i. Velocity 1400818 Coburn Tech Electrical, pneumatic, water, and heat sources.
Recent events (3)
  • — F (S) $6630
  • — C (S) $13260
  • — Z (S) $13260

View Luxottica Group's full OSHA safety record →