FAYETTEVILLE, GA —
OSHA Inspection: SALAZAR CASTILLO FRAMING, LLC
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of SALAZAR CASTILLO FRAMING, LLC in 125 OAKLEIGH MANNOR DR., FAYETTEVILLE, GA 30215 (NAICS 238130). OSHA activity number 344265319.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SALAZAR CASTILLO FRAMING, LLC
- Site address
- 125 OAKLEIGH MANNOR DR.
- City
- FAYETTEVILLE
- State
- GA
- ZIP
- 30215
- Mailing
- 2911 OLD CARRIAGE DR. SW, MARIETTA, GA 30060
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 4
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.102 A01
- Issued
- Feb 13, 2020
- Penalty
- Initial $2,545 · Current $2,545
General-duty citation text
29 CFR 1926.102(a)(1): The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation. (a) Lot 75 second floor: On or about 08/15/2019 the employer failed to ensure three employees performing framing operation were not exposed to hazardous struck-by conditions created by not wearing eye safety protection when using pneumatic framing nailers.
Recent events (3)
- — A (S) $2545
- — I (S) $1527
- — Z (S) $2545
1926.501 B13
- Issued
- Feb 13, 2020
- Penalty
- Initial $4,453 · Current $4,453
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) NOTE TO CSHO: USE THIS OPTION ONLY IN CASES WHERE THE INFEASIBILITY/GREATER HAZARD EXCEPTION IS NOT IN ISSUE. (a) Lot 75 second floor by garage - On or about 8/15/19, The employer allowed 3 employees to be exposed to a falls of up to 12 feet 9 inches to the ground below while performing framing operations from the second story floor of a new residential construction.
Recent events (3)
- — A (S) $4453
- — I (S) $2678.8
- — Z (S) $4453
5(a)(1)
- Issued
- Feb 13, 2020
- Penalty
- Initial $3,182 · Current $3,182
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees (a) Lot 75 second floor access - On or about 8/15/19, employees were using a job-made ladder which did not have filler blocks between the rungs/cleats of the ladder, exposing employees to fall hazards.
Recent events (3)
- — A (S) $3182
- — I (S) $1902.2
- — Z (S) $3182
1926.403 B01
- Issued
- Feb 13, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.403(b)(1): Employer did not ensure that electrical equipment is free from recognized hazards that are likely to cause death or serious physical harm to employees:ALLEGED VIOLATION DESCRIPTION (A.V.D.): (a) New Residential Dwelling lot 75, ground level: On or about 08/15/2019 and at times prior, the employer failed to inspect all the electrical cords prior to the start of the work shift. A 50 ft flexible cord used to power the Variable Speed Reciprocating Saw had a torn outer casing was missing strain relief and the ground pin was not being used
Recent events (3)
- — A (O) $0
- — I (O) $0
- — Z (O) $0
More inspections at Salazar Castillo Framing, LLC
View Salazar Castillo Framing, LLC's full OSHA safety record →
More inspections in this industry (NAICS 238130)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344265319.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.