Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: DYNASERV FLORIDA, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of DYNASERV FLORIDA, LLC in 309 SE 5TH ST, DANIA BEACH, FL 33004 (NAICS 561730). OSHA activity number 344266457.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Dynaserv Florida, LLC — free Get an email when a new federal OSHA severe-injury report for Dynaserv Florida, LLC is published. One employer, no account, unsubscribe in one click.
Site address
309 SE 5TH ST
City
DANIA BEACH
State
FL
ZIP
33004
Mailing
990 S FLAMINGO ROAD, DAVIE, FL 33325
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
561730
Employees
400
Ownership type
A

4 citations on file for this inspection.

1910.36 G02

Serious Gravity 1 1 instance 2 exposed
Issued
Jan 30, 2020
Abate by
Feb 6, 2020
Penalty
Initial $6,361 · Current $3,816 Reduced
29 CFR 1910.36(g)(2): Exit access(es) were not at least 28 inches (71.1 cm) wide at all points:    On or about 8/28/2019, at the mechanic shop of Dynaserv Florida LLC, 990 S Flamingo Rd, Davie, FL 33304, a passageway inside a stock room had a width of 20", exposing employees to the risk of being trapped in the event of a fire.
Recent events (2)
  • — I (S) $3816
  • — Z (S) $6361

1910.147 C04 I

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 30, 2020
Abate by
Feb 13, 2020
Penalty
Initial $10,603 · Current $7,422 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:    On or about 8/28/2019, at jobsite located at 309 SE 5th St, Dania Beach, FL 33004, the employer did not ensure that safety operating procedures were followed for clearing cut-grass from discharge chute of a riding lawnmower (i.e. eXmark Lazer Series S-type, Model LZS749EKC60400, Serial #315658119), exposing an employee to an amputation hazard.       In the Alternative:    OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees, in that employees were exposed to an amputation hazard:    On or about 8/26/2019, at jobsite located at 309 SE 5th St, Dania Beach, FL 33004, the employer did not ensure that safety operating procedures were followed for clearing cut-grass from discharge chute of a riding lawnmower (i.e. eXmark Lazer Series S-type, Model LZS749EKC60400, Serial #315658119), exposing an employee to an amputation hazard.
Recent events (2)
  • — I (S) $7422.1
  • — Z (S) $10603

1910.212 A03 II

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 30, 2020
Penalty
Initial $10,603 · Current $7,422 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):    On or about 8/28/2019, at jobsite located at 309 SE 5th St, Dania Beach, FL 33004, an employee was exposed to an amputation hazard while working with a riding lawnmower (i.e. eXmark Lazer Series S-type, Model LZS749EKC60400, Serial #315658119) with a broken discharge chute guard.
Recent events (2)
  • — I (S) $7422.1
  • — Z (S) $10603

1910.305 G02 III

Other-than-serious 1 instance 2 exposed
Issued
Jan 30, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:  On or about 8/28/2019, at the mechanic shop of Dynaserv Florida LLC, 990 S Flamingo Rd, Davie, FL 33304, employees were exposed to an electrical hazard when connected a fan (i.e. Model No. SFD1-500, Serial No. 1002770501) to an extension cord that lacked strain relief at the female end attachment plug.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Dynaserv Florida, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344266457.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.