Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GC REMODELING LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of GC REMODELING LLC in 81 COURT LAND STREET, PATERSON, NJ 07503 (NAICS 238140). OSHA activity number 344450531.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch GC Remodeling LLC — free Get an email when a new federal OSHA severe-injury report for GC Remodeling LLC is published. One employer, no account, unsubscribe in one click.
Establishment
GC REMODELING LLC
Site address
81 COURT LAND STREET
City
PATERSON
State
NJ
ZIP
07503
Mailing
41 MANCHESTER AVE, PATERSON, NJ 07502
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
2
Ownership type
A

9 citations on file for this inspection.

1926.451 B05 II

Serious Gravity 10 1 instance 2 exposed
Issued
Jan 31, 2020
Penalty
Initial $4,453 · Current $4,453
29 CFR 1926.451(b)(5)(ii): The end of a platform greater than 10 feet in length extended over its support more than 18 inches and the platform was not designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantilevered end.  a) Building Exterior: Employees were exposed to a 40 foot fall hazard while engaged in stucco activities from a pump jack scaffold. The end of the platform was not designed and installed so that the cantilevered portion of the platform was able to support employees without tipping, the pump jack scaffold had a 6 foot overhang over the support, on or about 11/15/2019.
Recent events (1)
  • — Z (S) $4453

1926.451 C03

Serious Gravity 10 1 instance 2 exposed
Issued
Jan 31, 2020
Penalty
Initial $4,453 · Current $4,453
29 CFR 1926.451(c)(3): Supported scaffold poles, legs, post, frames, and/or uprights were not plumb and braced to prevent swaying and displacement:  a) Building Exterior: Employees were working on a pump jack scaffold that was not plumb and braced at the bottom to prevent swaying and displacement, on or about 11/15/2019.
Recent events (1)
  • — Z (S) $4453

1926.451 F07

Serious Gravity 10 1 instance 2 exposed
Issued
Jan 31, 2020
Penalty
Initial $4,453 · Current $4,453
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered only under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling, or alteration and such activities were not performed by only experienced and trained employees:  a) Building Exterior: A pump jack scaffold was erected, without the supervision and direction of a competent person qualified in scaffold erection, on or about 11/15/2019
Recent events (1)
  • — Z (S) $4453

1926.451 G01

Serious Gravity 10 1 instance 2 exposed
Issued
Jan 31, 2020
Penalty
Initial $4,453 · Current $4,453
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level.  a) Building Exterior: Employees were exposed to a 40 foot fall hazard while working on a pump Jack Scaffold; that was not provided with a guardrail system or other means of fall protection in place, on or about 11/15/2019.
Recent events (1)
  • — Z (S) $4453

1926.452 J02

Serious Gravity 10 1 instance 2 exposed
Issued
Jan 31, 2020
Penalty
Initial $4,453 · Current $4,453
29 CFR 1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary.  Building Exterior: Employees were working on a pump jack scaffold that was not secured at the bottom by rigid triangular or equivalent braces, on or about 11/15/2019.
Recent events (1)
  • — Z (S) $4453

1926.454 A

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 31, 2020
Penalty
Initial $3,817 · Current $3,817
29 CFR 1926.454(a): The employer did not have each employee who performs work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards:  a) Building exterior: Employees were performing stucco work while on a pump jack scaffold without being trained by a person qualified in the subject matter to recognize the hazards associated with the  type of scaffold being used and to understand the procedures or control or minimize the hazards, on or bout 11/15/2019.
Recent events (1)
  • — Z (S) $3817

1926.454 B

Serious Gravity 10 1 instance 2 exposed
Issued
Jan 31, 2020
Penalty
Initial $4,453 · Current $4,453
29 CFR 1926.454(b): The employer did not have each employee involved in erecting, disassembling, moving, operating, repairing, maintaining, or inspecting a scaffold trained by a competent person to recognize any hazards associated with the work in question:   a) Building Exterior: The employer did not provided training for employees involved in erecting, disassembling, moving, operating, repairing, maintaining, or inspecting a pump jack scaffold by a competent person to recognize any hazards associated with the scaffold, on or about 11/15/2019.
Recent events (1)
  • — Z (S) $4453

1926.1053 B04

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 31, 2020
Penalty
Initial $2,545 · Current $2,545
29 CFR 1926.1053(b)(4): Ladders were used for purposes other than the purpose for which they were designed:  a) Building Exterior: Employees were using an aluminum extension ladder as a work bench and a top rail on a pump jack scaffold, on or about 11/15/2019.
Recent events (1)
  • — Z (S) $2545

1926.102 A01

Repeat Gravity 5 1 instance 2 exposed
Issued
Jan 31, 2020
Penalty
Initial $7,634 · Current $7,634
29 CFR 1926.102(a)(1): The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.  a) Building Exterior - Front: Employees were exposed to eye/face injuries while applying stucco. Employees were not protected with any type of eye/face protection, on or about 12/15/2019
Recent events (1)
  • — Z (R) $7634

View GC Remodeling LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344450531.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.