CLIFTON, NJ —
OSHA Inspection: GC REMODELING LLC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of GC REMODELING LLC. in 371 LAKEVIEW AVE, CLIFTON, NJ 07011 (NAICS 238140). OSHA activity number 345176366.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GC REMODELING LLC.
- Site address
- 371 LAKEVIEW AVE
- City
- CLIFTON
- State
- NJ
- ZIP
- 07011
- Mailing
- 41 MANCHESTER AVE, PATERSON, NJ 07502
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 4
- Ownership type
- A
Citations
8 citations on file for this inspection.
1926.102 A01
- Issued
- Aug 30, 2021
- Penalty
- Initial $7,022 · Current $7,022
General-duty citation text
29 CFR 1926.102(a)(1): The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation. a) Building Exterior - Front: Employees were exposed to eye/face injuries while applying stucco. Employees were not protected with any type of eye/face protection, on or about 3/3/21 The GC Remodeling LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.102(a)(1) , which was contained in OSHA inspection number 1459488, citation number 2, item number 1 and was affirmed as a final order on 8/31/20, with respect to a workplace located at 2 Genesse Ave Paterson NJ 07503.
Recent events (1)
- — Z (R) $7022
1926.451 F07
- Issued
- Aug 30, 2021
- Penalty
- Initial $8,192 · Current $8,192
General-duty citation text
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered only under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling, or alteration and such activities were not performed by only experienced and trained employees: a) Building Exterior Back: A pump jack scaffold was erected, without the supervision and direction of a competent person qualified in scaffold erection moving dismantling, or alteration, on or about 3/3/21. b)Building Exterior Back: Tubular welded pipe scaffold was erected, without the supervision and direction of a competent person qualified in erection, moving dismantling, or alteration, on or about 3/3/21 The GC Remodeling LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.451(f)(7, which was contained in OSHA inspection number 14450531, citation number 1, item number 3 and was affirmed as a final order on 8/31/20, with respect to a workplace located at 81 Courtland Street Paterson NJ 07503.
Recent events (1)
- — Z (R) $8192
1926.451 G01
- Issued
- Aug 30, 2021
- Penalty
- Initial $8,192 · Current $8,192
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level. a) Building Exterior: Employees were exposed to a 10 to 25 foot fall hazard while working on a pump Jack Scaffold; that was not provided with a guardrail system or other means of fall protection in place, on or about 3/3/21. The GC Remodeling LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.451(g)(1 , which was contained in OSHA inspection number 1445053, citation number 1, item number 4 and was affirmed as a final order on 8/31/20, with respect to a workplace located at 81 Courtland Street Paterson NJ 07503.
Recent events (1)
- — Z (R) $8192
1926.454 A
- Issued
- Aug 30, 2021
- Penalty
- Initial $7,022 · Current $7,022
General-duty citation text
29 CFR 1926.454(a): The employer did not have each employee who performs work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards: a) Building exterior: Employees were performing stucco work while on a pump jack scaffold without being trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures or control or minimize the hazards, on or bout 3/3/21. b) Building exterior: Employees were performing stucco work while on a tubular welded pipe scaffold without being trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures or control or minimize the hazards, on or bout 3/3/21. The GC Remodeling LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.454(a), which was contained in OSHA inspection number 1445053, citation number 1, item number 6 and was affirmed as a final order on 8/31/20, with respect to a workplace located at 81 Courtland Street Paterson NJ 07503.
Recent events (1)
- — Z (R) $7022
1926.454 B
- Issued
- Aug 30, 2021
- Penalty
- Initial $7,022 · Current $7,022
General-duty citation text
29 CFR 1926.454(b): The employer did not have each employee involved in erecting, disassembling, moving, operating, repairing, maintaining, or inspecting a scaffold trained by a competent person to recognize any hazards associated with the work in question: a) Building Exterior: The employer did not provided training for employees involved in erecting, disassembling, moving, operating, repairing, maintaining, or inspecting a pump jack scaffold by a competent person to recognize any hazards associated with the scaffold, on or about 3/3/21. The GC Remodeling LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.454(b), which was contained in OSHA inspection number 1445053, citation number 1, item number 7 and was affirmed as a final order on 8/31/20, with respect to a workplace located at 81 Courtland Street Paterson NJ 07503.
Recent events (1)
- — Z (R) $7022
1926.451 C03
- Issued
- Aug 30, 2021
- Penalty
- Initial $8,192 · Current $8,192
General-duty citation text
29 CFR 1926.451(c)(3): Supported scaffold poles, legs, post, frames, and/or uprights were not plumb and braced to prevent swaying and displacement: a) Building Exterior: Employees were working on a pump jack scaffold that was not plumb and braced at the bottom to prevent swaying and displacement, on or about 3/3/21. The GC Remodeling LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.451(c)(3), which was contained in OSHA inspection number 1445053, citation number 1, item number 2 and was affirmed as a final order on 8/31/20, with respect to a workplace located at 81 Courtland Street Paterson NJ 07503.
Recent events (1)
- — Z (R) $8192
1926.452 J02
- Issued
- Aug 30, 2021
- Penalty
- Initial $7,022 · Current $7,022
General-duty citation text
29 CFR 1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. a) Building Exterior: Employees were working on a pump jack scaffold that was not secured at the bottom by rigid triangular or equivalent braces, on or about 3/3/21. The GC Remodeling LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.452(j)(2), which was contained in OSHA inspection number 1445053, citation number 1, item number 5 and was affirmed as a final order on 8/31/20, with respect to a workplace located at 81 Courtland Street Paterson NJ 07503.
Recent events (1)
- — Z (R) $7022
1926.1053 B04
- Issued
- Aug 30, 2021
- Penalty
- Initial $7,022 · Current $7,022
General-duty citation text
29 CFR 1926.1053(b)(4): Ladders were used for purposes other than the purpose for which they were designed: a) Building Exterior: Employees were using an aluminum extension ladder as a work bench and a top rail on a pump jack scaffold, on or about 3/3/21. The GC Remodeling LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.1053(b)(4), which was contained in OSHA inspection number 1445053, citation number 1, item number 8 and was affirmed as a final order on 8/31/20, with respect to a workplace located at 81 Courtland Street Paterson NJ 07503.
Recent events (1)
- — Z (R) $7022
More inspections at GC Remodeling LLC.
View GC Remodeling LLC.'s full OSHA safety record →
More inspections in this industry (NAICS 238140)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345176366.