KEARNY, NJ ·
OSHA Inspection: KEARNY SMELTING & REFINING CORPORATION
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of KEARNY SMELTING & REFINING CORPORATION in 936 HARRISON AVE, KEARNY, NJ 07032 (NAICS 331423). OSHA activity number 344453444.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- KEARNY SMELTING & REFINING CORPORATION
- Site address
- 936 HARRISON AVE
- City
- KEARNY
- State
- NJ
- ZIP
- 07032
- Mailing
- 936 HARRISON AVE, KEARNY, NJ 07032
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Union (A)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331423
- Employees
- 25
- Ownership type
- Private (A)
Citations
6 citations on file for this inspection.
5(a)(1)
- Issued
- Feb 24, 2020
- Abate by
- Apr 10, 2020
- Penalty
- Initial $5,398 · Current $3,731 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that workers were exposed to severe burns by molten metal: a) Electric melting furnace area Employees were exposed to burn hazards from molten metal while attempting to clear blockage from induction furnace. On 11/11/19, an employee received burns to his hands, back and feet when he was splashed by molten metal after inserting 9 foot copper pipe filled with flux into induction furnace. Violation occurred on or about 11/11/19
Recent events (2)
- · I (S) $3731
- · Z (S) $5398
1910.25 B03
- Issued
- Feb 24, 2020
- Abate by
- Apr 10, 2020
- Penalty
- Initial $4,626 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.25(b)(3): The employer did not ensure that the stairs had uniform riser heights and tread depths between the landings: a) Electric Melting furnace area Stairs used to access electric furnace platform were not uniform in height exposing employees to trip and/or fall hazards. Condition observed on or about 11/14/19
Recent events (2)
- · I (S) $3000
- · Z (S) $4626
1910.25 C02
- Issued
- Feb 24, 2020
- Abate by
- Apr 10, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.25(c)(2): The employer did not ensure standard stairs have a maximum riser height of 9.5 inches (24 cm): a) Electric Melting furnace area Stairs used to access electric furnace platform had a riser height of greater than 9.5 inches exposing employees to trip and/or fall hazards. Condition observed on or about 11/14/19
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.28 B06 I
- Issued
- Feb 24, 2020
- Penalty
- Initial $5,398 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.28(b)(6)(i): Employees less than 4 feet (1.2 m) above uncovered or unguarded dangerous equipment were not protected from falling into or onto the dangerous equipment by a guardrail system or a travel restraint system. a) Electric Melting furnace area Employee performing servicing operations who stood on edge of induction furnace was exposed to molten metal and severe burns as the worker was not protected from falls. Condition observed on or about 11/14/19
Recent events (2)
- · I (S) $3000
- · Z (S) $5398
1910.132 C
- Issued
- Feb 24, 2020
- Abate by
- Apr 10, 2020
- Penalty
- Initial $5,398 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.132(c): Personal protective equipment was not of safe design and construction for the work to be performed: a) Electric Melting Furnace Area The employer did not require the use of molders shoes for employees who are exposed to the hazards of molten metal. On 11/11/19, an employee received burns to his feet when the furnace erupted and molten metal landed in the employee's boots. Condition occurred on or about 11/11/19
Recent events (2)
- · I (S) $3000
- · Z (S) $5398
1910.132 D01
- Issued
- Feb 24, 2020
- Abate by
- Apr 10, 2020
- Penalty
- Initial $5,398 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards were present, or were likely to be present, which necessitated the use of personal protective equipment: a) Electric Melting Furnace Area The employer's written workplace assessment did not identify the need for heat resistant gloves, aluminized sleeves/coats and molders shoes which are needed while working with molten metal. On 11/11/19, an employee received burns to his hands, back and feet when the furnace erupted and molten metal splashed the operator who was attempting to unclog the furnace. Condition observed on or about 11/14/19
Recent events (2)
- · I (S) $3000
- · Z (S) $5398
More inspections at Kearny Smelting & Refining Corporation
View Kearny Smelting & Refining Corporation's full OSHA safety record →
More inspections in this industry (NAICS 331423)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 344453444.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.