STEVENS POINT, WI —
OSHA Inspection: STEEL KING INDUSTRIES, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of STEEL KING INDUSTRIES, INC. in 2700 CHAMBER ST, STEVENS POINT, WI 54481 (NAICS 332312). OSHA activity number 344501267.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- STEEL KING INDUSTRIES, INC.
- Site address
- 2700 CHAMBER ST
- City
- STEVENS POINT
- State
- WI
- ZIP
- 54481
- Mailing
- 2700 CHAMBER ST, STEVENS POINT, WI 54481
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332312
- Employees
- 147
- Ownership type
- A
Citations
11 citations on file for this inspection.
1910.137 C02 VIII
- Issued
- Mar 18, 2020
- Abate by
- Apr 15, 2020
- Penalty
- Initial $7,210 · Current $5,047 Reduced
General-duty citation text
29 CFR 1910.137(c)(2)(viii): Electrical protective equipment shall be subjected to periodic electrical tests. Test voltages and the maximum intervals between tests shall be in accordance with Table I-4 and Table I-5. During the month of October 2019 and thereafter electrically rated gloves used to test blown fuses on the Cincinnati shear had not been tested at intervals required, exposing employees to electrical shock hazards.
Recent events (2)
- — I (S) $5047
- — Z (S) $7210
1910.147 C04 II
- Issued
- Mar 18, 2020
- Abate by
- May 6, 2020
- Penalty
- Initial $9,012 · Current $6,308 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): The procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A-D): (a) The energy control procedure used for the Cut Off did not provide specific procedural steps to drain air pressure nor specific requirements for testing the machine to determine and verify the effectiveness of lockout devices. (b) The energy control procedure used for the Niagara Punch Press did not provide specific procedural steps to drain air pressure nor specific requirements for testing the machine to determine and verify the effectiveness of lockout devices. (c) The energy control procedure used for the Band Saw (Marvel) did not provide specific procedural steps to address the hydraulic and pneumatic energy sources nor specific requirements for testing the machine to determine and verify the effectiveness of lockout devices. (d) The energy control procedure used for the HTC Brake Press did not provide specific procedural steps to address the hydraulic energy source. (e) The energy control procedure used for the Pacific Brake Press did not provide specific procedural steps to address the hydraulic energy source.
Recent events (2)
- — I (S) $6308.4
- — Z (S) $9012
1910.147 C05 II
- Issued
- Mar 18, 2020
- Abate by
- Apr 15, 2020
- Penalty
- Initial $7,210 · Current $5,047 Reduced
General-duty citation text
29 CFR 1910.147(c)(5)(ii): Lockout devices and tagout devices shall be singularly identified; shall be the only devices(s) used for controlling energy; shall not be used for other purposes; The Master lock on the Verson mechanical press used to keep the guard on would also be used as a lockout device when changing the cut off blade.
Recent events (2)
- — I (S) $5047
- — Z (S) $7210
1910.147 C06 I
- Issued
- Mar 18, 2020
- Abate by
- May 6, 2020
- Penalty
- Initial $7,210 · Current $5,047 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed. The employer failed to conduct periodic inspections to ensure the procedures were accurate and employees understood their responsibilities under the energy control procedure being inspected.
Recent events (2)
- — I (S) $5047
- — Z (S) $7210
1910.147 C07 I A
- Issued
- Mar 18, 2020
- Abate by
- May 6, 2020
- Penalty
- Initial $9,012 · Current $6,308 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A): Each authorized employee shall receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control. Set up operators performing set up tasks for the mechanical power presses and hydraulic press brakes were not trained as an authorized personnel under the control of hazardous energy exposing employees to the accidental/inadvertent restart of equipment.
Recent events (2)
- — I (S) $6308.4
- — Z (S) $9012
1910.147 D
- Issued
- Mar 18, 2020
- Abate by
- Apr 15, 2020
- Penalty
- Initial $9,012 · Current $6,308 Reduced
General-duty citation text
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): On or about the week of November 11, 2019, employees were exposed to machine hazards associated with moving parts when they engaged in die changing activities on the Niagara press. The employer did not ensure that employees implemented energy control application steps prior to allowing them to change dies. The machine was not deenergized prior to the employee engaging in the servicing / maintenance activity. As a result, the remaining applicable energy control elements, involving machine isolation [1910.147(d)(3)], lockout/tagout device application [1910.147(d)(4)], dissipation of residual energy [1910(d)(5)(i)], and verification of isolation [1910.147(d)(6)] were not implemented to protect employees from machine hazards.
Recent events (2)
- — I (S) $6308.4
- — Z (S) $9012
1910.217 D09 I
- Issued
- Mar 18, 2020
- Abate by
- Apr 15, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.217(d)(9)(i): The employer shall establish a die setting procedure that will insure compliance with paragraph (c) of this section. The die setting procedures for the Niagara punch press and Verson power press did not outline the requirement to apply a lockout device or die blocks when performing a die change.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 F03 II D
- Issued
- Mar 18, 2020
- Abate by
- Apr 15, 2020
- Penalty
- Initial $9,012 · Current $6,308 Reduced
General-duty citation text
29 CFR 1910.147(f)(3)(ii)(D): Each authorized employee shall affix a personal lockout or tagout device to the group lockout device, group lockbox, or comparable mechanism when he or she begins work, and shall remove those devices when he or she stops working on the machine or equipment being serviced or maintained. (a) During the month of November 2019 and thereafter, each employee performing servicing work with the Cincinnati Shear to change the blade did not affix a personal lockout device.
Recent events (2)
- — I (S) $6308.4
- — Z (S) $9012
1910.217 C02 I A
- Issued
- Mar 18, 2020
- Abate by
- Apr 15, 2020
- Penalty
- Initial $9,012 · Current $6,308 Reduced
General-duty citation text
29 CFR 1910.217(c)(2)(i)(a): It shall prevent entry of hands or fingers into the point of operation by reaching through, over, under or around the guard; (a) The Verson No. 7 (S/N: 11079) part rev press had guards on the side which allowed access to the point of operation exposed employees to struck by hazards. (b) The Niagara (Model: 5000, S/N: 29) punch press had guards on the right and left sides which allowed access to the point of operation.
Recent events (2)
- — I (S) $6308.4
- — Z (S) $9012
1910.217 E03
- Issued
- Mar 18, 2020
- Abate by
- May 6, 2020
- Penalty
- Initial $9,012 · Current $6,308 Reduced
General-duty citation text
29 CFR 1910.217(e)(3): Training of maintenance personnel. It shall be the responsibility of the employer to insure the original and continuing competence of personnel caring for, inspecting, and maintaining power presses. Maintenance personnel performing maintenance, servicing, and inspections were not trained in safe working procedures for inspecting and maintaining press production systems.
Recent events (2)
- — I (S) $6308.4
- — Z (S) $9012
1910.178 L06
- Issued
- Mar 18, 2020
- Abate by
- Apr 15, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(6): Certification. The employer shall certify that each operator has been trained and evaluated as required by this paragraph (l). The certification shall include the name of the operator, the date of the training, the date of the evaluation, and the identity of the person(s) performing the training or evaluation. During the month of December 2019, the employer did not certify each operator who completed the training and evaluation to operate the powered industrial vehicles.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Steel King Industries, INC.
View Steel King Industries, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332312)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344501267.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.