Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: HAILO WIND SYSTEMS, USA INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of HAILO WIND SYSTEMS, USA INC. in 1395 MINERAL SPRINGS RD, ELBERTON, GA 30635 (NAICS 332999). OSHA activity number 344501358.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Hailo Wind Systems, USA INC. — free Get an email when a new federal OSHA severe-injury report for Hailo Wind Systems, USA INC. is published. One employer, no account, unsubscribe in one click.
Site address
1395 MINERAL SPRINGS RD
City
ELBERTON
State
GA
ZIP
30635
Mailing
1395 MINERAL SPRINGS RD, ELBERTON, GA 30635
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332999
Employees
15
Ownership type
A

9 citations on file for this inspection.

1910.95 D01

Serious Gravity 5 2 instances 3 exposed
Issued
Apr 30, 2020
Abate by
Jun 17, 2020
Penalty
Initial $3,856 · Current $2,314 Reduced

Hazardous substances 8111

29 CFR 1910.95(d)(1): When information indicated that any employee's exposure equaled or exceed the 8-hour time-weighted average of 85 decibels, the employer did not develop and implement a monitoring program:  a) Hailo Wind Systems, USA Inc., Elberton, Ga - Sound level meter reading taken while an employee was cutting aluminum rungs and reject ladders with a radial arm saw showed noise levels between 98-102 dBA. Initial noise monitoring was not performed to determine the noise levels the employee(s) were exposed to, on or about 12/10/19.  b) Hailo Wind Systems, USA Inc., Elberton, Ga - Sound level meter reading taken while an employee was grinding/buffing metal pieces showed noise levels between 94-96 dBA. Initial noise monitoring was not performed to determine the noise levels the employee(s) were exposed to, on or about 12/10/19.
Recent events (2)
  • — I (S) $2313.6
  • — Z (S) $3856

1910.134 C01

Serious Gravity 1 1 instance 3 exposed
Issued
Apr 30, 2020
Abate by
May 27, 2020
Penalty
Initial $2,313 · Current $1,388 Reduced
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use:  Hailo Wind Systems, USA Inc., Elberton, Ga - Laser operators were provided and required to use a half mask, negative pressure respirator when working with the dust collector. A written respiratory protection program was not developed and implemented, on or about 12/10/19.
Recent events (2)
  • — I (S) $1387.8
  • — Z (S) $2313

1910.134 D01 I

Serious Gravity 1 1 instance 3 exposed
Issued
Apr 30, 2020
Abate by
May 27, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.134(d)(1)(i): Selection of appropriate respirators was not based on the respiratory hazard(s) to which the worker was exposed and user factors that affect respirator performance and reliability:  Hailo Wind Systems, USA Inc., Elberton, Ga - Laser operators were provided and required to use a half mask, negative pressure respirator when working with the dust collector. The cartridges provided were for protection against organic vapors and acid gasses and not for protection against dust, on or about 12/10/19.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 E01

Serious Gravity 1 1 instance 3 exposed
Issued
Apr 30, 2020
Abate by
May 27, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: Note:  The employer may discontinue an employee's medical evaluations when the employee is no longer required to use a respirator.  Hailo Wind Systems, USA Inc., Elberton, Ga - Laser operators were provided and required to use a half mask, negative pressure respirator when working with the dust collector. A medical evaluation was not conducted for each employee required to wear a respirator, on or about 12/10/19.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 F01

Serious Gravity 1 1 instance 3 exposed
Issued
Apr 30, 2020
Abate by
May 27, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT):  Hailo Wind Systems, USA Inc., Elberton, Ga - Laser operators were provided and required to use a half mask, negative pressure respirator when working with the dust collector. Fit tests were not performed, on or about 12/10/19.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 K01

Serious Gravity 1 1 instance 3 exposed
Issued
Apr 30, 2020
Abate by
May 27, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.134(k)(1): The employer did not provide respirator training that ensured that each employee could demonstrate knowledge of at least the following elements: Why the respirator is necessary and how improper fit, usage, or maintenance can compromise the protective effect of the respirator; What the limitations and capabilities of the respirator are; How to use the respirator effectively in emergency situations, including situations in which the respirator malfunctions; How to inspect, put on and remove, use, and check the seals of the respirator; What the procedures are for maintenance and storage of the respirator, and How to recognize medical signs and symptoms that may limit or prevent the effective use of respirators:  Hailo Wind Systems, USA Inc., Elberton, Ga - Laser operators were provided and required to use a half mask, negative pressure respirator when working with the dust collector. Respiratory protection training as required by the standard was not provided, on or about 12/10/19.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 E01

Serious Gravity 1 1 instance 15 exposed
Issued
Apr 30, 2020
Abate by
May 27, 2020
Penalty
Initial $2,313 · Current $1,388 Reduced
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:  Hailo Wind Systems, USA Inc., Elberton, Ga - Employees working in the manufacturing of metal products for wind systems were exposed to hazards such as, but not limited to, metal dust, welding gasses and lubricants. The written hazard communication program was not updated to reflect changes of the globally harmonized system (GHS), on or about 12/10/19.
Recent events (2)
  • — I (S) $1387.8
  • — Z (S) $2313

1910.1200 G08

Serious Gravity 1 1 instance 15 exposed
Issued
Apr 30, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(g)(8):   The employer did not maintain in the workplace copies of the required safety data sheets for each hazardous chemical, and did not ensure that they were readily accessible during each work  shift to employees when they were in their work area(s)  Hailo Wind Systems, USA Inc., Elberton, Ga - Employees working in the manufacturing of metal products for wind systems were exposed to hazards such as, but not limited to lubricants. The material safety data sheets (MSDS) were not updated to the safety data sheets (SDS) in accordance to standard, on or about 12/10/19.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 H03 IV

Serious Gravity 1 1 instance 15 exposed
Issued
Apr 30, 2020
Abate by
May 27, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(3)(iv):   The details of the hazard communication program developed by the employer, did not include an explanation of the labels received on shipped containers and the workplace labeling system used by their employer; the safety data sheet, including the order of information and how employee could obtain and use the appropriate hazard information:  Hailo Wind Systems, USA Inc., Elberton, Ga - Employees working in the manufacturing of metal products for wind systems were exposed to hazards such as, but not limited to, metal dust, welding gasses and lubricants. The training did not include an explanation of the labeling system and safety data sheets as required by the GHS, on or about 12/10/19.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Hailo Wind Systems, USA INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344501358.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.