Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,249Inspections Most recent open 2026-08-20 Last loaded 2026-08-24

OSHA Inspection: NUTRIEN AG SOLUTIONS, INC.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of NUTRIEN AG SOLUTIONS, INC. in 13649 SE 69TH BLVD, JASPER, FL 32052 (NAICS 325312). OSHA activity number 344520606.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Nutrien AG Solutions, INC. for free Get an email when a new federal OSHA severe-injury report for Nutrien AG Solutions, INC. is published. One employer, no account, unsubscribe in one click.
Site address
13649 SE 69TH BLVD
City
JASPER
State
FL
ZIP
32052
Mailing
15843 S E 78TH PL, WHITE SPRINGS, FL 32096
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Union (A)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325312
Employees
600
Ownership type
Private (A)

2 citations on file for this inspection.

1910.134 G03 VI A

Serious Gravity 5 1 instance 2 exposed
Issued
May 26, 2020
Abate by
Jun 19, 2020
Penalty
Initial $8,193 · Current $4,916 Reduced

Hazardous substances 1480

29 CFR 1910.134(g)(3)(vi)(A): Employees located outside the immediately dangerous to life or health atmosphere were not equipped with pressure demand or other positive pressure SCBAs, or a pressure demand or other positive pressure supplied-air respirator with auxiliary SCBA:     a) On or about and at times prior to December 16, 2019, employees working as a Spotter during molten Sulfur rail car tank venting operations, which is right outside an immediately dangerous to life or health atmosphere, were exposed to Hydrogen Sulfide in that a pressure demand or other positive pressure SCBAs, or a pressure demand or other positive pressure supplied-air respirator with auxiliary SCBA, was not required to be readily available for the employee's use in the event of an emergency.
Recent events (2)
  • · I (S) $4915.8
  • · Z (S) $8193

5(a)(1)

Serious Gravity 5 1 instance 2 exposed
Issued
May 26, 2020
Abate by
Jun 19, 2020
Penalty
Initial $8,193 · Current $4,916 Reduced

Hazardous substances 1480

OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to inhalation hazards:    a) On or about and at times prior to December 16, 2019, during molten Sulfur rail car tank venting operations, employees were exposed to hazardous concentrations of Hydrogen Sulfide gas in that the employer's written emergency procedure did not include instructions for upwind evacuation in the event of an emergency.    b) On or about and at times prior to December 16, 2019, during molten Sulfur rail car tank venting operations, employees were exposed to hazardous concentrations of Hydrogen Sulfide gas in that the written procedure did not restrict the venting operation be conducted only when the wind direction was away from any personnel involved in the operation.
Recent events (2)
  • · I (S) $4915.8
  • · Z (S) $8193

View Nutrien AG Solutions, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 344520606.