Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: CHELTENHAM CONSTRUCTION SERVICES, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CHELTENHAM CONSTRUCTION SERVICES, INC. in SOUTHEAST CORNER OF OLD PARK LANE, SWANSEA, IL 62226 (NAICS 238130). OSHA activity number 344558457.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Cheltenham Construction Services, INC. for free Get an email when a new federal OSHA severe-injury report for Cheltenham Construction Services, INC. is published. One employer, no account, unsubscribe in one click.
Site address
SOUTHEAST CORNER OF OLD PARK LANE
City
SWANSEA
State
IL
ZIP
62226
Mailing
PO BOX 1654, WASHINGTON, MO 63090
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Union (A)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
6
Ownership type
Private (A)

2 citations on file for this inspection.

1926.501 B13

Repeat Gravity 5 1 instance 2 exposed
Issued
Feb 6, 2020
Abate by
Mar 25, 2020
Penalty
Initial $63,613 · Current $38,168 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):     On or about January 15, 2020, two employees engaged in sheeting operations were not protected from falling approximately 8 feet to a lower level.    Cheltenham Construction Services, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(13), which was contained in OSHA inspection number 1104683, citation number 1, item number 1 and was affirmed as a final order on 4-6-16, with respect to a workplace located at 1137 Ironhorse Court, in Wentzville Missouri.
Recent events (2)
  • · I (R) $38168
  • · Z (R) $63613

1926.502 E02

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 6, 2020
Abate by
Mar 25, 2020
Penalty
Initial $12,724 · Current $0 Reduced
29 CFR 1926.502(e)(2): Positioning devices were not secured to an anchorage capable of supporting at least twice the potential impact load of an employee's fall or 3,000 pounds (13.3 kN), whichever was greater:    On or about January 15, 2020, an employee was exposed to an approximately 8 foot fall to a lower level.  A fall positioning device was secured to a single wooden truss and trusses were not braced as required.
Recent events (2)
  • · I (S) $0
  • · Z (S) $12724

View Cheltenham Construction Services, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 344558457.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.