Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: FULTON COUNTY PROCESSING, LTD.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of FULTON COUNTY PROCESSING, LTD. in 7800 OH-109, DELTA, OH 43515 (NAICS 331221). OSHA activity number 344573290.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Fulton County Processing, LTD. — free Get an email when a new federal OSHA severe-injury report for Fulton County Processing, LTD. is published. One employer, no account, unsubscribe in one click.
Site address
7800 OH-109
City
DELTA
State
OH
ZIP
43515
Mailing
PO BOX 67, DELTA, OH 43515
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331221
Employees
142
Ownership type
A

5 citations on file for this inspection.

1910.179 G01 V

Serious Gravity 5 1 instance 3 exposed
Issued
Mar 4, 2020
Penalty
Initial $8,525 · Current $8,525
29 CFR 1910.179(g)(1)(v): Pendant control box(es) were not clearly marked for identification of functions:  Fulton County Processing, LTD, Delta, OH: On or about January 22, 2020, the employer failed to ensure that the Shawbox overhead hoist, S/N  08F32740 pendant control boxes located at Pack line #2 were clearly marked for identification of function there by exposing employees to a struck by hazard.
Recent events (1)
  • — Z (S) $8525

1910.179 J02 III

Serious Gravity 5 1 instance 3 exposed
Issued
Mar 4, 2020
Abate by
Mar 27, 2020
Penalty
Initial $8,675 · Current $8,675
29 CFR 1910.179(j)(2)(iii): A certification record which includes the date of inspection, the signature of the person who performed the inspection and the serial number, or other identifier, of the hook inspected, was not maintained:  Fulton County Processing, LTD, Delta, OH, Slitter 2 Line: On or about January 22, 2020, the employer failed to ensure that a Shawbox overhead hoist, S/N 08F32740 hook and throat opening was inspected monthly.  Annual inspection revealed throat opening worn past 10 percent and should have replaced immediately there by exposing employees to a struck by hazard.
Recent events (1)
  • — Z (S) $8675

1910.179 J03

Serious Gravity 5 1 instance 3 exposed
Issued
Mar 4, 2020
Abate by
Mar 27, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.179(j)(3)(iv): The employer did not ensure that worn, cracked or distorted parts such as pins, bearings, shafts, gears, rollers, locking and clamping devices were changed when needed.  Fulton County Processing, LTD, Delta, OH, Slitter 2 line: On or about January 22, 2020, the employer failed to replace a Shawbox overhead hoist, S/N  08F32740 hook that was found to be worn past 10 percent during an annual inspection conducted on June 10, 2019, there by exposing employees to a struck by hazard.
Recent events (1)
  • — Z (S) $0

1910.212 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 4, 2020
Penalty
Initial $8,675 · Current $8,675
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  Fulton County Processing, LTD, Delta, OH, Slitter 2 Line: On or about January 22, 2020, the employer failed to guard in going nip points on a powered conveyor. An employee measuring the width of a roll of steel suffered an amputation while the roll was moving down the conveyor exposing the employee to an amputation hazards.
Recent events (1)
  • — Z (S) $8675

1910.303 G01

Serious Gravity 5 2 instances 3 exposed
Issued
Mar 4, 2020
Penalty
Initial $6,940 · Current $6,940
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:  a. Fulton County Processing, LTD, Delta, OH, Slitter 2 Line: On or about January 22, 2020, the employer did not provide sufficient access and working space to a 480 electrical volt panel (CD1) to permit the ready and safe operation and maintenance of equipment.  b. Fulton County Processing, LTD, Delta, OH, Slitter 2 Line: On or about January 22, 2020, the employer did not provide sufficient access and working space to a 480 volt electrical panel (CD2) to permit the ready and safe operation and maintenance of equipment.
Recent events (1)
  • — Z (S) $6940

View Fulton County Processing, LTD.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344573290.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.