MILFORD, OH —
OSHA Inspection: ALCON CONNECTORS
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of ALCON CONNECTORS in 1308 US RT. 50 STE. 100, MILFORD, OH 45150 (NAICS 335999). OSHA activity number 344586078.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ALCON CONNECTORS
- Site address
- 1308 US RT. 50 STE. 100
- City
- MILFORD
- State
- OH
- ZIP
- 45150
- Mailing
- 1308 US RT. 50 STE. 100, MILFORD, OH 45150
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 335999
- Employees
- 9
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.212 A01
- Issued
- Apr 1, 2020
- Abate by
- Apr 20, 2020
- Penalty
- Initial $5,398 · Current $3,779 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices,electronic safety devices, etc. a) On or about January 27, 2020 the Cleveland tapping machines did not utilize a guarding method that would prevent employees from getting caught in the point of operation. b) On or about January 27, 2020 the General Machinery stand sander did not utilize a guarding method that would be prevent employees from getting caught in the point of operation of the 6" belt.
Recent events (2)
- — I (S) $3778.6
- — Z (S) $5398
1910.217 C01 I
- Issued
- Apr 1, 2020
- Penalty
- Initial $5,398 · Current $0 Reduced
General-duty citation text
29 CFR 1910.217(c)(1)(i): Safeguarding the point of operation- General requirements.: It shall be the responsibility of the employer to provide and insure the usage of "point of operation guards" or properly applied and adjusted point of operation devices on every operation performed on a mechanical power press. See Table O-10. a) On or about January 27, 2020 the employer did not ensure that the Loshbough Jordan Press was provided with point of operation guarding.
Recent events (2)
- — I (S) $0
- — Z (S) $5398
1910.303 B01
- Issued
- Apr 1, 2020
- Abate by
- Apr 27, 2020
- Penalty
- Initial $3,084 · Current $2,159 Reduced
General-duty citation text
29 CFR 1910.303(b)(1): Examination, installation, and use of equipment -- Examination. Electric equipment shall be free from recognized hazards that are likely to cause death or serious physical harm to employees. Safety of equipment shall be determined using the following considerations: a) On or about January 27, 2020 the employer was utilizing a cheater switch on the portable belt sander in place of having an on/off switch at the equipment.
Recent events (2)
- — I (S) $2158.8
- — Z (S) $3084
1910.305 G01 IV
- Issued
- Apr 1, 2020
- Abate by
- Apr 27, 2020
- Penalty
- Initial $3,084 · Current $0 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and cables. Use of flexible cords and cables. Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables may not be used: As a substitute for the fixed wiring of a structure; a) On or about January 27, 2020 an extension cord was used to power supply power to the General Machinery belt sander.
Recent events (2)
- — I (S) $0
- — Z (S) $3084
1910.212 B
- Issued
- Apr 1, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(b): Anchoring fixed machinery. Machines designed for a fixed location shall be securely anchored to prevent walking or moving. a) On or about January 27, 2020 the Jordan Press was not anchored to the floor to prevent walking or moving.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Alcon Connectors