AMELIA, OH —
OSHA Inspection: ALCON CONNECTORS
Follow-up inspection · Safety discipline
At a glance
On , OSHA opened a follow-up safety inspection of ALCON CONNECTORS in 1132 FERRIS ROAD, AMELIA, OH 45102 (NAICS 335999). OSHA activity number 345176762.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ALCON CONNECTORS
- Site address
- 1132 FERRIS ROAD
- City
- AMELIA
- State
- OH
- ZIP
- 45102
- Mailing
- 1132 FERRIS ROAD, AMELIA, OH 45102
What kind of inspection was it?
- Inspection type
- Follow-up (F)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 335999
- Employees
- 13
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.303 B01 I
- Issued
- Apr 21, 2021
- Abate by
- Jun 8, 2021
- Penalty
- Initial $2,574 · Current $1,300 Reduced
General-duty citation text
29 CFR 1910.303(b)(1)(i): Suitability for installation and use in conformity with the provisions of this subpart; Note to paragraph (b)(1)(i) of this section: Suitability of equipment for an identified purpose may be evidenced by listing or labeling for that identified purpose. a) On or about March 3, 2021, the drop pendant electrical outlet box, which had the Cummins Drill Press SN#29567 and Palmgren 2" Belt Grinder plugged into the receptacle, was not suitable for installation as it was designed to be used as a wall mounted outlet.
Recent events (2)
- — I (S) $1300
- — Z (S) $2574
1910.305 G02 III
- Issued
- Apr 21, 2021
- Penalty
- Initial $4,291 · Current $0 Reduced
General-duty citation text
29 CFR 1910.305(g)(2)(iii):Flexible cords and cables shall be connected to devices and fittings so that strain relief is provided that will prevent pull from being directly transmitted to joints or terminal screws. a) On or about March 3, 2021, the power cord to the Cummins Drill Press SN#29567 did not have strain relief at the plug or the entry point into the machine.
Recent events (2)
- — I (S) $0
- — Z (S) $4291
More inspections at Alcon Connectors