KENILWORTH, IL —
OSHA Inspection: JM SUPERIOR ROOFING LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of JM SUPERIOR ROOFING LLC in 125 WOODSTOCK AVE., KENILWORTH, IL 60043 (NAICS 238160). OSHA activity number 344591854.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- JM SUPERIOR ROOFING LLC
- Site address
- 125 WOODSTOCK AVE.
- City
- KENILWORTH
- State
- IL
- ZIP
- 60043
- Mailing
- 1716 N. BALDWIN AVE., WAUKEGAN, IL 60085
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 2
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.501 B13
- Issued
- Jan 31, 2020
- Abate by
- Feb 6, 2020
- Penalty
- Initial $4,048 · Current $2,450 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) Pitched Roof Surface - On or about January 28, 2020, employees were not protected from the hazard of falling while performing roofing work on a pitched roof having a ground to eave height of approximately 20 feet. b) Flat Roof Surface - On or about January 28, 2020, employees were not protected from the hazard of falling while performing roofing work on a flat roof having a ground to eave height of approximately 16 feet. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $2450
- — Z (S) $4048
1926.552 A01
- Issued
- Jan 31, 2020
- Penalty
- Initial $2,313 · Current $1,375 Reduced
General-duty citation text
29 CFR 1926.552(a)(1): The employer did not comply with the manufacturer's specifications and limitations applicable to the operation of all hoists and elevators: a) Flat Roof Surface - On or about January 28, 2020, a material hoist was used for climbing to reach a flat roof surface where roofing work was being conducted. No abatement certification or documentation required for this violation.
Recent events (2)
- — I (S) $1375
- — Z (S) $2313
1926.1053 B01
- Issued
- Jan 31, 2020
- Abate by
- Feb 6, 2020
- Penalty
- Initial $2,313 · Current $1,375 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) Pitched Roof Surface - On or about January 28, 2020, employees were exposed to the hazard of falling approximately 20 feet where a portable extension ladder did not extend at least 3 feet above a pitched roof deck landing surface. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (S) $1375
- — Z (S) $2313
More inspections at JM Superior Roofing LLC
View JM Superior Roofing LLC's full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344591854.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.