Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: DIXON TICONDEROGA COMPANY

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of DIXON TICONDEROGA COMPANY in 2525 N. CASALOMA DR., APPLETON, WI 54913 (NAICS 322299). OSHA activity number 344621636.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Dixon Ticonderoga Company — free Get an email when a new federal OSHA severe-injury report for Dixon Ticonderoga Company is published. One employer, no account, unsubscribe in one click.
Site address
2525 N. CASALOMA DR.
City
APPLETON
State
WI
ZIP
54913
Mailing
2525 N. CASALOMA DR., APPLETON, WI 54913
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
322299
Employees
240
Ownership type
A

1 citation on file for this inspection.

1910.147 C04 II

Serious Gravity 5 1 instance 8 exposed
Issued
Mar 9, 2020
Abate by
Apr 6, 2020
Penalty
Initial $9,012 · Current $4,506 Reduced
29 CFR 1910.147(c)(4)(ii):  Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)[A], (c)(4)(ii)[B], (c)(4)(ii)[C], and (c)(4)(ii)[D]:     On February 12, 2020, the employer failed to clearly identify all of the specific steps to be followed by employees to isolate and disable the Titan Line Shaft conveyor along the "Big Line" in order to safely de-energize the equipment and control the energy hazards and to prevent unintentional exposure to hazardous energy. The current procedures lacked the following:      1. The purpose, scope and authorization of the energy control procedure;  2. Identify and locate energy disconnect switches and/or valves to control isolation;  3. Sequential steps to be followed to protect employees from hazards;  4. Identify the steps to take in order to ensure residual and/or stored energy has been removed;  5. Specific steps to verify and test that de-energization and isolation has been accomplished;  6. Provide steps for restart.
Recent events (2)
  • — I (S) $4506
  • — Z (S) $9012

View Dixon Ticonderoga Company's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344621636.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.