OSHA Inspection: DIXON TICONDEROGA COMPANY

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of DIXON TICONDEROGA COMPANY in 1097 EHLERS ROAD, NEENAH, WI 54956 (NAICS 322230). OSHA activity number 346536246.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Dixon Ticonderoga Company — free Get an email when a new federal OSHA severe-injury report for Dixon Ticonderoga Company is published. One employer, no account, unsubscribe in one click.
Site address
1097 EHLERS ROAD
City
NEENAH
State
WI
ZIP
54956
Mailing
1097 EHLERS ROAD, NEENAH, WI 54956
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
322230
Employees
70
Ownership type
A

6 citations on file for this inspection.

1910.23 B01

Serious Gravity 1 2 instances 2 exposed
Issued
Aug 15, 2023
Abate by
Sep 13, 2023
Penalty
Initial $7,366 · Current $3,683 Reduced
29 CFR  1910.23(b)(1): Ladder rungs, steps, and cleats are parallel, level, and uniformly spaced when the ladder is in position for use;  On or about February 21, 2023, at an establishment located at 1097 Ehlers Street, in Neenah, Wisconsin; in the Display Area, the 3001 Flexo Press had a ladder on the color deck numbers 4 through 6 used for cleaning and other activities did not have the ladder rungs uniformly spaced exposing employees to trip and fall hazards.
Recent events (2)
  • — I (S) $3683
  • — Z (S) $7366

1910.147 C06 I

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Aug 15, 2023
Abate by
Sep 20, 2023
Penalty
Initial $15,625 · Current $0 Reduced
29 CFR  1910.147(c)(6)(i):  The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.  On or about March 1, 2023, Dixon Ticonderoga Company had not completed a periodic inspection of the 3001 Flexo Press energy control procedures at least annually to ensure the energy control procedures were accurate, steps in the energy control procedure are being followed, and the employees involved knew their responsibilities under the procedure exposing employees to inadvertent/accidental restart of equipment.
Recent events (2)
  • — I (S) $0
  • — Z (S) $15625

1910.219 F01 I

Serious Gravity 5 5 instances 2 exposed
Issued
Aug 15, 2023
Abate by
Sep 13, 2023
Penalty
Initial $12,278 · Current $6,139 Reduced
29 CFR  1910.219(f)(1)(i):  Gears. Gears shall be guarded in accordance with one of the following methods: By a complete enclosure;  On or about February 21, 2023, at an establishment located at 1097 Ehlers Street, in Neenah, Wisconsin; in the Display Area for the FMC 3001 Flexo Press, S/N:  3833, the six print decks had gears which rotated during operation each had a guard that was not fully enclosed allowing access from the top and behind exposing employees to caught in hazards.
Recent events (2)
  • — I (S) $6139
  • — Z (S) $12278

1910.219 M01 I

Serious Gravity 5 6 instances 2 exposed
Issued
Aug 15, 2023
Abate by
Jan 2, 2024
Penalty
Initial $12,278 · Current $0 Reduced
29 CFR  1910.219(m)(1)(i): Standard conditions shall be secured by the use of the following materials. Expanded metal, perforated or solid sheet metal, wire mesh on a frame of angle iron, or iron pipe securely fastened to floor or to frame of machine.   On or about February 21, 2023, at an establishment located at 1097 Ehlers Street, in Neenah, Wisconsin; in the Display Area for the FMC 3001 Flexo Press, S/N:  3833, the expanded metal guards on each of the print decks was secured with a hinge which did not protect from being inadvertently dislodged or removed exposing employees to caught between hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $12278

1910.147 C04 II

Deleted Repeat Gravity 10 2 instances 2 exposed
Issued
Aug 15, 2023
Abate by
Sep 13, 2023
Penalty
Initial $156,259 · Current $0 Reduced
29 CFR  1910.147(c)(4)(ii): The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, the following:  (a)  On or about February 21, 2023, at an establishment located at 1097 Ehlers Street, in Neenah, Wisconsin; in the Display Area for the FMC 3001 Flexo Press, S/N:  3833,  the employer did not document each of the  specific procedural steps for de-energization when performing cleaning activities to include but not limit the anilox roller, print roller/plate, and carry drum exposing employees to caught between hazards.  (b)  On or about February 21, 2023, at an establishment located at 1097 Ehlers Street, in Neenah, Wisconsin; in the Display Area for the FMC 3001 Flexo Press, S/N:  3833,  the employer did not document each of the  specific procedural steps for de-energization when performing set up activities exposing employees to caught between hazards.   The Dixon Ticonderoga Company was previously cited for a violation of this occupational safety and health standard which was contained in OSHA inspection number 1580960, citation number 2 item number 1 and was affirmed as a final order on June 27, 2022, with respect to a workplace located at 1097 Ehlers Road, in Neenah, Wisconsin.  The Dixon Ticonderoga Company was previously cited for a violation of this occupational safety and health standard which was contained in OSHA inspection number 1462163, citation number 1 item number 1 and was affirmed as a final order on April 8, 2020, with respect to a workplace located at 2525 North Casaloma Drive, in Appleton, Wisconsin.
Recent events (2)
  • — I (R) $0
  • — Z (R) $156259

1910.147 D

Repeat Gravity 10 1 instance 1 exposed
Issued
Aug 15, 2023
Abate by
Sep 20, 2023
Penalty
Initial $0 · Current $78,130
29 CFR  1910.147(d):  The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6):  (a)  On or about February 21, 2023, at an establishment located at 1097 Ehlers Street, in Neenah, Wisconsin; in the Display Area, employees were exposed to machine hazards associated with moving parts when they engaged in cleaning activities on the FMC 3001 Flexo Press.  The employer did not ensure that employees implemented energy control application steps or equivalent protective measures prior to allowing them to clean the drum.  The machine was not deenergized prior to the employee engaging in the servicing / maintenance activity.  (b)  On or about February 21, 2023, at an establishment located at 1097 Ehlers Street, in Neenah, Wisconsin; in the Display Area, employees were exposed to machine hazards associated with moving parts when they engaged in set up activities on the FMC 3001 Flexo Press.  The employer did not ensure that employees implemented energy control application steps or equivalent protective measures prior to allowing them to set up the press.  The machine was not deenergized prior to the employee engaging in the servicing / maintenance activity.  As a result, the remaining applicable energy control elements, involving machine isolation [1910.147(d)(3)], lockout/tagout device application [1910.147(d)(4)], dissipation of residual energy [1910(d)(5)(i)], and verification of isolation [1910.147(d)(6)] were not implemented to protect employees from machine hazards.  The Dixon Ticonderoga Company was previously cited for a violation of this occupational safety and health standard which was contained in OSHA inspection number 1580960, citation number 1 item number 1b and was affirmed as a final order on June 27, 2022, with respect to a workplace located at 1097 Ehlers Road, in Neenah, Wisconsin.
Recent events (2)
  • — I (R) $78129.5
  • — Z (R) $0

View Dixon Ticonderoga Company's full OSHA safety record →