OSHA Inspection: PHIL LONG FORD, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PHIL LONG FORD, LLC in 1212 MOTOR CITY DRIVE, COLORADO SPRINGS, CO 80906 (NAICS 441110). OSHA activity number 344636907.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Phil Long Ford, LLC — free Get an email when a new federal OSHA severe-injury report for Phil Long Ford, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
PHIL LONG FORD, LLC
Site address
1212 MOTOR CITY DRIVE
City
COLORADO SPRINGS
State
CO
ZIP
80906
Mailing
1212 MOTOR CITY DRIVE, COLORADO SPRINGS, CO 80906
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
441110
Employees
140
Ownership type
A

4 citations on file for this inspection.

5(a)(1)

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Apr 23, 2020
Penalty
Initial $8,193 · Current $0 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that repair technicians were exposed to crushing and struck-by hazards in the vehicle service area:     a) Service Bay 17: On or about February 18, 2020, two workers performed maintenance adjacent to and under an vehicle elevated by a Rotary automotive lift that had not been lowered to the safety locks.     Abatement Note: This condition was corrected.  Abatement certification is required for this item to describe measures to prevent recurrence (see enclosed Certification of Corrective Action Worksheet).
Recent events (2)
  • — I (S) $0
  • — Z (S) $8193

1910.212 A01

Other-than-serious 1 instance 1 exposed
Issued
Apr 23, 2020
Abate by
May 5, 2020
Penalty
Initial $6,554 · Current $5,000 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    a) Diesel Service Area: On or about February 18, 2020, and at times prior, workers were exposed to struck by hazards while operating a pneumatic Norco press Model # 78024, that did not have a guard to prevent discharged debris from striking the operator.    Abatement Note: Abatement certification is required for this item (see enclosed Certification of Corrective Action Worksheet).
Recent events (2)
  • — I (O) $5000
  • — Z (S) $6554

1910.25 B01

Other-than-serious 1 instance 6 exposed
Issued
Apr 23, 2020
Abate by
Jun 10, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.25(b)(1): The employer did not ensure handrails, stair rail systems, and guardrail systems were provided in accordance with 1910.28:  a) Supply room:  On or about February 18, 2020, and at times prior, workers were exposed to hazards while ascending and descending a 44.75 inch wide stair system equipped with a removable hand rail that did not meet minimum height requirements and was not suitable as a stair rail system.  NOTE: Installation guidance for a suitable hand rail and stair rail are found in 1910.28 and 1910.29.  Abatement Note: Abatement certification is required for this item (see enclosed Certification of Corrective Action Worksheet).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 G02 I

Other-than-serious 1 instance 6 exposed
Issued
Apr 23, 2020
Abate by
Jun 10, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):  a) Parts Department: On or about February 18, 2020, and at times prior, workers were exposed to hazards while stocking and pulling parts in an area where unguarded light fixtures were positioned less than eight feet above the working level.  Abatement Note: Abatement certification is required for this item (see enclosed Certification of Corrective Action Worksheet).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Phil Long Ford, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344636907.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.