OSHA Inspection: TEKNI-PLEX, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of TEKNI-PLEX, INC. in 252 HOSEA RD., LAWRENCEVILLE, GA 30046 (NAICS 326140). OSHA activity number 344663745.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Tekni-Plex, INC. — free Get an email when a new federal OSHA severe-injury report for Tekni-Plex, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
TEKNI-PLEX, INC.
Site address
252 HOSEA RD.
City
LAWRENCEVILLE
State
GA
ZIP
30046
Mailing
252 HOSEA RD., LAWRENCEVILLE, GA 30046
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326140
Employees
167
Ownership type
A

3 citations on file for this inspection.

1910.147 C06 I

Serious Gravity 10 1 instance 10 exposed
Issued
Apr 2, 2020
Abate by
May 19, 2020
Penalty
Initial $13,494 · Current $9,000 Reduced
29 CFR 1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed.    On 3/2/2020, at the Lawrenceville facility, the employer did not ensure a periodic inspection of the Lockout program occurred. Deficiencies included:    a  - newly installed equipment did not have specific written Lockout procedures   b - Lockout procedures were missing magnitudes of energies   c - Lockout procedures were not reviewed by at least two Authorized employees
Recent events (2)
  • — I (S) $9000
  • — Z (S) $13494

1910.147 C07 I A

Serious Gravity 10 1 instance 10 exposed
Issued
Apr 2, 2020
Abate by
May 19, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation.  On 3/2/2020, at the Lawrenceville facility, the employer did not ensure employees performing service and maintenance work to production equipment were trained as Authorized employees.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A01

Serious Gravity 10 6 instances 10 exposed
Issued
Apr 2, 2020
Abate by
May 19, 2020
Penalty
Initial $13,494 · Current $9,000 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks.    3/2/2020, at the Printing lines in production, the employer did not ensure moving and rotating parts were guarded to ensure employees did not come into contact with ingoing nip points and rotating parts.
Recent events (2)
  • — I (S) $9000
  • — Z (S) $13494

View Tekni-Plex, INC.'s full OSHA safety record →