THOMASTON, GA —
OSHA Inspection: NATURAL PACK INC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of NATURAL PACK INC in 108 MCINTOSH PARKWAY, THOMASTON, GA 30286 (NAICS 444220). OSHA activity number 344678685.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NATURAL PACK INC
- Site address
- 108 MCINTOSH PARKWAY
- City
- THOMASTON
- State
- GA
- ZIP
- 30286
- Mailing
- P. O. BOX 30352, SANTA BARBARA, CA 93130
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 444220
- Employees
- 12
- Ownership type
- A
Citations
27 citations on file for this inspection.
5(a)(1)
- Issued
- Sep 1, 2020
- Abate by
- Sep 28, 2020
- Penalty
- Initial $6,940 · Current $0 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees by exposing employees to struck-by hazards. On or about 03/06/2020, the company's two (2) portable gantry cranes located in the chemical mixing area of the facility were not inspected as required. Daily to frequent basis inspections were not being completed thus increasing the chance to overload the cranes. Used to complete tasks such as, but not limited to; filling net with wet moss that can weigh approximately 100 lbs. (+) or bleaching, preserving, and dyeing moss; employees were not protected from potential struck-by hazards.
Recent events (3)
- — J (S) $0
- — C (S) $6940
- — Z (S) $6940
1910.22 A01
- Issued
- Sep 1, 2020
- Abate by
- Sep 28, 2020
- Penalty
- Initial $10,409 · Current $5,268 Reduced
General-duty citation text
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms, service rooms, and walking-working surfaces were not kept in a clean, orderly, and sanitary condition: a) Warehouse Floor: On or about 03/06/2020, employees working in the packing and storage areas of the warehouse were not protected from potential slip hazards in that, rainwater accumulated on the flooring. b) Warehouse Area, Chemical Mix Area: On or about 03/06/2020, employees were exposed to potential slip hazards in that, a mixture of water and chemicals created slick patches on the flooring throughout the chemical mixing area. c) Warehouse Area, Outside Women's Restroom: On or about 03/06/2020, the employer exposed employees to a trip hazard in that an extension cord, used as a power source for a water cooler was plugged into a wall outlet. The extensions cord laid outside of the women's restroom door on the floor, creating a trip hazard. d) Warehouse Area - Near Sprinkler System: On or about 03/06/2020, the employer exposed employees to potential trip and /or slip hazard because large amounts of trash and boxes were scattered about the flooring in the work area. e) Warehouse Area, Men and Women Restrooms - On or about 03/18/2020, the employer exposed employees to the slip and sanitary health hazards in that, deficient plumbing conditions caused leaks that spilled onto the flooring; in both the male and female restrooms. f) Warehouse - Side Dock Area Rollup Doors - On or about 03/06/2020, employees working in the packing area of the facility were potentially exposed to a fall hazard of approximately four (+) ft. Although employees were allowed to use the dock/bay door opening to get fresh air, railing to prevent falls from dock/bay; was not installed. g) Warehouse - Roof Area - On or about 03/06/2020, employees were not protected from fall hazards in that, the use of conventional fall protection devices were not enforce by the employer. Employees who accessed the roof area when performing servicing and/or maintenance on the roof were exposed to a fall of approximately 33 feet high from the roof to ground level.
Recent events (3)
- — J (S) $5268
- — C (S) $10409
- — Z (S) $10409
1910.28 B01 I
- Issued
- Sep 1, 2020
- Abate by
- Sep 28, 2020
- Penalty
- Initial $6,940 · Current $0 Reduced
General-duty citation text
29 CFR 1910.28(b)(1)(i): The employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2 m) or more above a lower level was protected from falling: a) Warehouse - Side Dock Area Rollup Doors - On or about 03/06/2020, employees working in the packing area of the facility were potentially exposed to a fall hazard of approximately four (+) ft. Although employees were allowed to use the dock/bay door opening to get fresh air, railing to prevent falls from dock/bay; was not installed. b) Warehouse - Roof Area - On or about 03/06/2020, employees were not protected from fall hazards in that, the use of conventional fall protection devices were not enforce by the employer. Employees who accessed the roof area when performing servicing and/or maintenance on the roof were exposed to a fall of approximately 33 feet high from the roof to ground level.
Recent events (3)
- — J (S) $0
- — C (S) $6940
- — Z (S) $6940
1910.37 A03
- Issued
- Sep 1, 2020
- Abate by
- Sep 14, 2020
- Penalty
- Initial $5,205 · Current $0 Reduced
General-duty citation text
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed: a) Warehouse - Chemical Mixing Area Back Exit Door- On or about 03/11/2020, employees who worked in the chemical mixing area of the facility were potentially exposed to fire hazards in that, wooden pallets of moss blocked an exit door.
Recent events (3)
- — J (S) $0
- — C (S) $5205
- — Z (S) $5205
1910.37 B05
- Issued
- Sep 1, 2020
- Abate by
- Sep 14, 2020
- Penalty
- Initial $6,940 · Current $4,164 Reduced
General-duty citation text
29 CFR 1910.37(b)(5): Each doorway or passage along an exit access that could be mistaken for an exit was not marked "Not an Exit" or similar designation, or be identified by a sign indicating its actual use (e.g. closet): a) Warehouse - Chemical Mixing Area - On or about 03/06/2020, employees were exposed to fire hazards in that a door located near stacks of dry moss in the chemical area was not marked "Not an Exit". The doorway which can be mistakenly used as an exit, leads to an enclosed courtyard. b) Warehouse - Near Maintenance Shop Area - On or about 03/06/2020, employees were exposed to fire hazards in that a door located near the maintenance shop was not marked "Not an Exit". The doorway which can be mistakenly used as an exit, leads to an enclosed courtyard.
Recent events (3)
- — J (S) $4164
- — C (S) $6940
- — Z (S) $6940
1910.101 B
- Issued
- Sep 1, 2020
- Abate by
- Sep 14, 2020
- Penalty
- Initial $6,940 · Current $4,164 Reduced
General-duty citation text
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in CFR 1910.6: a) Warehouse Area, Chemical Mixing Area Exit Door and in proximity to the Back Roll-up Door/ Ramp - On or about 03/06/2020, the employer exposed employees to struck-by and/or fire hazards in that the employer failed to ensure that compressed gases, such as but not limited to, propane, were properly stored. Employees who worked in the proximity to unchained propane cylinders were not protected should the cylinders rupture, be hit by a powered industrial vehicle, or fall and become a projectile.
Recent events (3)
- — J (S) $4164
- — C (S) $6940
- — Z (S) $6940
1910.133 A01
- Issued
- Sep 1, 2020
- Abate by
- Sep 21, 2020
- Penalty
- Initial $10,409 · Current $5,268 Reduced
General-duty citation text
29 CFR 1910.133(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation: (a) Warehouse Chemical Mixing Area - On or about 03/06/2020, the employer failed to ensure that employees who worked with chemicals such as, but not limited to, Propylene Glycol, Glycerine 99.7, Keyazine Yellow EA, and Turquoise 8280 were provided with and/or utilized safety eyewear (safety glasses and/or chemical goggles, etc.).
Recent events (3)
- — J (S) $5268
- — C (S) $10409
- — Z (S) $10409
1910.138 A
- Issued
- Sep 1, 2020
- Abate by
- Sep 14, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.138(a): The employer did not select and require employees to use appropriate hand protection when employees hands were exposed to hazardous condition(s) (a) Warehouse Chemical Mixing Area - On or about 03/06/2020, the employer did not ensure that employees use gloves for hand and skin protection against chemical hazards such as, but not limited to, Glycerine 99.7 and Triethylene Glycol.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1910.151 C
- Issued
- Sep 1, 2020
- Abate by
- Sep 14, 2020
- Penalty
- Initial $8,675 · Current $0 Reduced
General-duty citation text
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: a) Warehouse, Chemical Mix Area - On or about 03/06/2020, the employer failed to ensure employees who worked with chemicals that have a high pH such as, but not limited to, Sodium Hypochlorite (pH=11.5-13.5) did not have the appropriate facilities to use to quickly flush the eye(s).
Recent events (3)
- — J (S) $0
- — C (S) $8675
- — Z (S) $8675
1910.134 D01 III
- Issued
- Sep 1, 2020
- Abate by
- Sep 21, 2020
- Penalty
- Initial $20,819 · Current $0 Reduced
General-duty citation text
29 CFR 1910.134(d)(1)(iii): The employer did not identify and evaluate the respiratory hazard(s) in the workplace; including a reasonable estimate of employee exposures to respiratory hazards and identification of the contaminant's chemical state and physical form: a) Warehouse Chemical Mixing Area - On or about 03/06/2020, the employer did not adequately identify and evaluate the respiratory hazards for employees who work with chemicals including, but not limited to, Triethylene Glycol and Ethylene Glycol. Natural Pack Inc was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.134(d)(l)(iii), which was contained in OSHA inspection number 1359602, citation number 1, item number 1 group C and was affirmed as a final order on 02/26/2019, with respect to a workplace located at 100 Gibraltar Rd. Reading, PA 19606. Natural Pack Inc was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.134(d)(1)(iii), which was contained in OSHA inspection number 1359602, citation number 1, item number 1 group C and was affirmed as a final order on 02/26/2019, with respect to a workplace located at 100 Gibraltar Rd. Reading, PA 19606.
Recent events (3)
- — J (S) $0
- — C (R) $20819
- — Z (R) $20819
1910.178 L01 I
- Issued
- Sep 1, 2020
- Abate by
- Sep 14, 2020
- Penalty
- Initial $8,675 · Current $0 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator was competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): a) Warehouse Area - On or about 03/06/2020, the employer exposed employees throughout the production and/or warehouse areas to struck-by hazards in that untrained employees were authorized to operate the company's Toyota Electric Forklift Truck (model# 9BRU18 s/n 9BRU18-396240), Toyota Order Picker (model# 8BPU15), Skyjack Scissor Lift (model# SJ3226), and Toyota Forklift Truck (model# 8FGCU25 s/n 96871).
Recent events (3)
- — J (S) $0
- — C (S) $8675
- — Z (S) $8675
1910.303 E01
- Issued
- Sep 1, 2020
- Abate by
- Sep 21, 2020
- Penalty
- Initial $10,409 · Current $0 Reduced
General-duty citation text
29 CFR 1910.303(e)(1): Identification of manufacturer and ratings. Electric equipment may not be used unless the following markings have been placed on the equipment: (i) The manufacturer's name, trademark, or other descriptive marking by which the organization responsible for the product may be identified; and (ii) Other markings giving voltage, current, wattage, or other ratings as necessary. (A) Markings were not placed on electric equipment as required. a) Warehouse Area, Near Maintenance Shop - On or about 03/06/2020, the employer exposed employees to electrical hazards, in that the electrical panel located near the maintenance shop was not marked and/or labeled with the voltage, current, wattage, or other ratings as required. Employees regularly access the companys 480/277V 3-phase electrical panel when turning on lights and machinery at the facility. b) Warehouse Area, Unlocked Chain-Linked Fenced Electrical Equipment Area - On or about 03/06/2020, the employer exposed employees to electrical hazards, in that the electrical panel located near the transformer and electrical meters was not marked and/or labeled with the voltage, current, wattage, or other ratings as required. Employees regularly access the companys 480/277V 3-phase electrical panel when turning on lights and machinery at the facility.
Recent events (3)
- — J (S) $0
- — C (S) $10409
- — Z (S) $10409
1910.303 F02
- Issued
- Sep 1, 2020
- Abate by
- Sep 14, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: a) Warehouse Area, Near Maintenance Shop- On or about 03/06/2020, the employer exposed employees to electrical hazards, in that the employer did not ensure that all of the breakers in 120/208V 3-Phase electrical panel box (SP-6) were labeled for their purpose as required. b) Warehouse Area, Unlocked Chain-Linked Fenced Electrical Equipment Area- On or about 03/11/2020, the employer exposed employees to electrical hazards in that, the employer did not ensure that all of the breakers in a 480/277V 3-Phase electrical panel box (C15) were labeled for their purpose as required.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1910.303 G02 I A
- Issued
- Sep 1, 2020
- Abate by
- Sep 14, 2020
- Penalty
- Initial $10,409 · Current $0 Reduced
General-duty citation text
29 CFR 1910.303(g)(2)(i)(A): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or by location in a room, vault, or similar enclosure that is accessible only to qualified persons: a) Warehouse Area, Near Maintenance Shop- On or about 03/06/2020, the employer exposed employees to electrical hazards, in that the employer did not ensure that two electrical panels (480/277V and 120/208V) 3-phase were fully closed and locked. b) Warehouse Area, Near Storage Racks- On or about 03/11/2020, the employer exposed employees to electrical hazards, in that the employer did not ensure that two electrical panels, (480/277V and 120/208V) 3-phase, were fully closed and locked. c) Warehouse Area, Unlocked Chain-Linked Fenced Electrical Equipment Area - On or about 03/06/2020, the employer exposed employees to electrical hazards, in that the employer did not ensure that two electrical panels, (480/277V and 120/208V) 3-phase, were fully closed and locked. The chain-linked fencing was meant to be used as a barrier/guarding to prevent unauthorized employees from assessing the electrical equipment room. The fenced area, which also contained meters and a transformer, was not closed and/ or properly secured, as required.
Recent events (3)
- — J (S) $0
- — C (S) $10409
- — Z (S) $10409
1910.304 F01 IV
- Issued
- Sep 1, 2020
- Abate by
- Sep 14, 2020
- Penalty
- Initial $5,205 · Current $0 Reduced
General-duty citation text
29 CFR 1910.304(f)(1)(iv): Over-current devices were not readily accessible to each employee or authorized building management personnel. a) Warehouse Area, Near Storage Racks - On or before March 11, 2020, employees were exposed to potential shock and/or fire hazards, in that wooden pallets of moss blocked two 480/277V and 120/208V, 3-phase electrical panels.
Recent events (3)
- — J (S) $0
- — C (S) $5205
- — Z (S) $5205
1910.333 B02 I
- Issued
- Sep 1, 2020
- Abate by
- Sep 28, 2020
- Penalty
- Initial $5,205 · Current $3,726 Reduced
General-duty citation text
29 CFR 1910.333(b)(2)(i): The employer did not maintain a written copy of the procedures outlined in paragraph (b)(2) of 29 CFR 1910.333 and did not make it available for inspection by the Assistant Secretary of Labor and his or her authorized representatives: a) Facility-wide - On or about 03/06/2020, written procedures identifying and/or detailing electrical hazards likely present at the facility were not established, developed or maintained at the facility, and were unavailable for inspection.
Recent events (3)
- — J (O) $3726
- — C (S) $5205
- — Z (S) $5205
1910.334 A04
- Issued
- Sep 1, 2020
- Penalty
- Initial $5,205 · Current $4,123 Reduced
General-duty citation text
29 CFR 1910.334(a)(4): Portable electric equipment and flexible cords that was used in highly conductive work locations (such as those inundated with water or other conductive locations) or in job locations where employees were likely to contact water or conductive liquids were not approved for those locations: a) Warehouse- Near Packing Area: On or about 03/06/2020, flexible cords used as temporary wiring were stored and/ or utilized in a wet location. An electrical extension cord, approved for residential use, was plugged into outlet and used to as a power source for a (Skilsaw) circular saw, was lying in a puddle of water.
Recent events (3)
- — J (S) $4123
- — C (S) $5205
- — Z (S) $5205
1910.1200 F06 I
- Issued
- Sep 1, 2020
- Abate by
- Sep 14, 2020
- Penalty
- Initial $6,940 · Current $4,164 Reduced
General-duty citation text
29 CFR 1910.1200(f)(6)(i): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the information required by 29 CFR 1910.1200(f)(1)(i) through 29 CFR 1910.1200(f)(1)(v) a) Warehouse Area - Chemical Mixing and Dyeing Area - 55 gallon drum: On or before 03/06/2020, appropriate labels and/or hazard warnings were not placed on secondary container of hazardous chemicals. The employer did not ensure that chemicals used for dying and/or preservation including, but not limited to, Propylene Glycol, Glycerin 99.7, Sodium Hypochlorite, and Turquoise 8280 were properly labeled. b) Warehouse Area - Chemical Mixing and Dyeing Area - totes: On or before 03/06/2020, appropriate labels and/or hazard warnings were not placed on secondary container of hazardous chemicals. The employer did not ensure that chemicals used for dying and/or preservation including, but not limited to, Propylene Glycol, Glycerin 99.7, Sodium Hypochlorite, and Turquoise 8280 were properly labeled.
Recent events (3)
- — J (S) $4164
- — C (S) $6940
- — Z (S) $6940
1910.1200 G08
- Issued
- Sep 1, 2020
- Abate by
- Sep 14, 2020
- Penalty
- Initial $5,205 · Current $0 Reduced
General-duty citation text
29 CFR 1910.1200(g)(8):The employer did not maintain in the workplace copies of the required safety data sheets for each hazardous chemical. a) Warehouse Area - SDS Book: On or before 3/06/2020, employees were exposed to chemical hazards in that, the employer failed to place copies of the safety data sheets (SDS) for chemicals used in the dying and preservation of moss where they could be assessable to employees. Chemicals used at the facility include, but are not limited to; Propylene Glycol, Magnesium Chloride Flakes, Glycerine 99.7, and Propane.
Recent events (3)
- — J (S) $0
- — C (S) $5205
- — Z (S) $5205
1910.1200 H01
- Issued
- Sep 1, 2020
- Abate by
- Sep 14, 2020
- Penalty
- Initial $5,205 · Current $4,123 Reduced
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: a) Production and Warehouse Areas: On or before 3/06/2020, employees were not trained on the hazardous chemicals utilized in the workplace. Chemicals used at the site include, but are not limited to; Triethylene Glycol, Glycerine 99.7, Sodium Hypochlorite, Keyazine Yellow EA, Propane, and Turquoise 8280.
Recent events (3)
- — J (O) $4123
- — C (S) $5205
- — Z (S) $5205
1910.1200 H03 IV
- Issued
- Sep 1, 2020
- Abate by
- Sep 14, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(3)(iv): The details of the hazard communication program developed by the employer, did not include an explanation of the safety data sheet, including the order of information and how employee could obtain and use the appropriate hazard information: a) Production and Warehouse Areas: On or before March 6, 2020, employer failed to provide training or information to employees working with hazardous chemicals on the details of outline in the new hazard communication standard which encompasses the Global Harmonization System (GHS).
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1910.141 D02 II
- Issued
- Sep 1, 2020
- Abate by
- Sep 21, 2020
- Penalty
- Initial $10,409 · Current $0 Reduced
General-duty citation text
29 CFR 1910.141(d)(2)(ii): Lavatories were not provided with hot and cold, or tepid running water: a) Warehouse Area, Men's Bathroom - On or about 03/18/2020, the employer exposed employees to sanitary health hazards in that there is no hot or tepid running water (only cold). b) Warehouse Area, Women's Bathroom - On or about 03/18/2020, the employer exposed employees to sanitary health hazards in that, hot or tepid water was not available at the facility. Natural Pack Inc was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.141(d)(1)(ii), which was contained in OSHA inspection number 1323185, citation number 1, item number 3 and was affirmed as a final order on 01/18/2019, with respect to a workplace located at 100 Gibraltar Rd. Reading, PA 19606.
Recent events (3)
- — J (R) $0
- — C (R) $10409
- — Z (R) $10409
1910.176 B
- Issued
- Sep 1, 2020
- Abate by
- Sep 21, 2020
- Penalty
- Initial $10,409 · Current $0 Reduced
General-duty citation text
29 CFR 1910.176(b): Material stored in tiers was not stacked, blocked, interlocked or limited in height so that it was stable and secure against sliding and collapse: a) Warehouse: On or about March 6, 2020, employees who work in the warehouse area of the facility were not protected from struck-by hazards in that, boxes of moss and wood were improperly stacked. The haphazardly stack boxes were encroached on the aisle ways creating a hazard for pedestrians and power industrial equipment operations. Natural Pack Inc was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.176(b), which was contained in OSHA inspection number 1323185, citation number 1, item number 4 and was affirmed as a final order on 01/18/2019, with respect to a workplace located at 100 Gibraltar Rd. Reading, PA 19606.
Recent events (3)
- — J (R) $0
- — C (R) $10409
- — Z (R) $10409
1910.134 K06
- Issued
- Sep 1, 2020
- Abate by
- Sep 14, 2020
- Penalty
- Initial $347 · Current $0 Reduced
General-duty citation text
29 CFR 1910.134(k)(6): The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer: a) Warehouse Area- Entire Facility: On or about 3/06/2020, to minimize exposure to nuisance dust and/or a variety of chemicals, an employee was provided an N95 dust-mask for use at the facility. Use of dust masks is voluntary however, the employer failed to provide a copy of and to educate employees on the information contained in Appendix D. The Natural Pack, Inc was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.134(k)(6), which was contained in OSHA inspection number 1359602, citation number 2, item number 1 and was affirmed as a final order on 02/26/2019, with respect to a workplace located at 100 Gibraltar Rd. Reading, PA 19606.
Recent events (3)
- — J (R) $0
- — C (R) $347
- — Z (R) $347
1910.157 C01
- Issued
- Sep 1, 2020
- Abate by
- Sep 14, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: a) Warehouse Area - Inside Chin-Linked Fenced Area, near Electrical Switch Panel: On or about March 6, 2020 the employer exposed employees to fire hazards in that three (ABC) portable fire extinguishers were placed on floor and not mounted as required. b) Warehouse Area -Near Sprinkler System: On or about March 6, 2020 the employer exposed employees to fire hazards in that two portable (ABC) fire extinguishers were placed on floor and not mounted as required.
Recent events (3)
- — J (O) $0
- — C (O) $0
- — Z (O) $0
1910.303 B02
- Issued
- Sep 1, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) Warehouse- Packing Area: On or about March 6, 2020, the employer exposed employees to fire hazards in that an APC UL 1363 120V ac Model# PE63DP, relocatable power tap and extension cord were daisy chained and installed for use with a Craftsman Heater (model# CMXEHA060FAV).
Recent events (3)
- — J (O) $0
- — C (O) $0
- — Z (O) $0
1910.305 G01 IV A
- Issued
- Sep 1, 2020
- Abate by
- Sep 14, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a) Warehouse - Water Cooler Near Bathrooms: On or about March 6, 2020 the employer exposed employees to electrical shock hazards in that an extension cord was used with an Water Cooler (Model # Unknown) as a permanent source for wiring.
Recent events (3)
- — J (O) $0
- — C (O) $0
- — Z (O) $0
More inspections at Natural Pack INC
View Natural Pack INC's full OSHA safety record →
More inspections in this industry (NAICS 444220)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344678685.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.