MARYSVILLE, OH —
OSHA Inspection: FLORENTINO VELASCO
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of FLORENTINO VELASCO in 6871 RED TOP CT, MARYSVILLE, OH 43040 (NAICS 238160). OSHA activity number 344744933.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FLORENTINO VELASCO
- Site address
- 6871 RED TOP CT
- City
- MARYSVILLE
- State
- OH
- ZIP
- 43040
- Mailing
- 2003 LINWOOD AVE, COLUMBUS, OH 43207
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 4
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B13
- Issued
- May 13, 2020
- Abate by
- May 26, 2020
- Penalty
- Initial $4,048 · Current $4,048
General-duty citation text
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502. Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems. On or about May 7, 2020, employees performing roofing work on a new build single family home were not protected from falling.
Recent events (1)
- — Z (S) $4048
1926.1053 B01
- Issued
- May 13, 2020
- Abate by
- May 26, 2020
- Penalty
- Initial $2,892 · Current $2,892
General-duty citation text
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support. On or about May 7, 2020, ladders used to gain access to upper landing surfaces to perform roofing work were not extended at least 3 feet above the upper landing surface.
Recent events (1)
- — Z (S) $2892
More inspections at Florentino Velasco
View Florentino Velasco's full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344744933.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.