ADDISON, AL —
OSHA Inspection: SOUTHERN ENERGY HOMES, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of SOUTHERN ENERGY HOMES, INC. in 18025 COUNTY ROAD 41, ADDISON, AL 35540 (NAICS 321991). OSHA activity number 344758313.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SOUTHERN ENERGY HOMES, INC.
- Site address
- 18025 COUNTY ROAD 41
- City
- ADDISON
- State
- AL
- ZIP
- 35540
- Mailing
- P.O.BOX 390, ADDISON, AL 35540
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321991
- Employees
- 230
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.22 A02
- Issued
- Jun 29, 2020
- Abate by
- Jul 17, 2020
- Penalty
- Initial $10,814 · Current $5,407 Reduced
General-duty citation text
29 CFR 1910.22(a)(2): Floor(s) of workroom(s) were not maintained in a clean and, so far as possible, a dry condition: (a) On or about 05/20/2020 - Trim Department area, hoses were allowed to accumulate on the floor exposing employees to slip and fall hazards.
Recent events (2)
- — I (O) $5407
- — Z (S) $10814
1910.212 A01
- Issued
- Jun 29, 2020
- Abate by
- Jul 17, 2020
- Penalty
- Initial $13,494 · Current $0 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) On or about May 13, 2020 - Trim Department, Station #25, Miter Saw, Model: DWS715, Serial Number: 401890, the rotating blade was not guarded, exposing employees to an amputation hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $13494
1910.37 B04
- Issued
- Jun 29, 2020
- Abate by
- Jul 17, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(4): Signs were not posted along the exit access indicating the direction of travel to the nearest exit and exit discharge when the direction of travel to the exit or exit discharge was not immediately apparent: (a) On or about 10/30/2019 - Production building area, signs were not posted along the exit access to indicate the direction of travel to the nearest exit door.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Southern Energy Homes, INC.
View Southern Energy Homes, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 321991)
More inspections in AL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344758313.