Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: KOS REMODELING, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of KOS REMODELING, INC. in 225 E FOREST AVE, WHEATON, IL 60187 (NAICS 238160). OSHA activity number 344773858.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch KOS Remodeling, INC. — free Get an email when a new federal OSHA severe-injury report for KOS Remodeling, INC. is published. One employer, no account, unsubscribe in one click.
Site address
225 E FOREST AVE
City
WHEATON
State
IL
ZIP
60187
Mailing
7710 S. RUTHERFORD, BURBANK, IL 60459
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
6
Ownership type
A

4 citations on file for this inspection.

1926.451 B05 II

Serious Gravity 5 1 instance 2 exposed
Issued
Jun 22, 2020
Abate by
Aug 15, 2020
Penalty
Initial $3,181 · Current $1,591 Reduced
29 CFR 1926.451(b)(5)(ii): Each platform greater than 10 feet in length shall not extend over its support more than 18 inches (46 cm), unless it is designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantilevered end.    On or about June 4, 2020, the ladder jack scaffold platform extended over 18 inches beyond its support.   Employees engaged in residential roofing operations were exposed to fall hazards while working on the ladder jack platform.    Abatement documentation is required for this item in accordance with 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $1591
  • — Z (S) $3181

1926.451 G01 I

Serious Gravity 10 1 instance 2 exposed
Issued
Jun 22, 2020
Abate by
Aug 15, 2020
Penalty
Initial $4,453 · Current $2,227 Reduced
29 CFR 1926.451(g)(1)(i): Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold shall be protected by a personal fall arrest system.      On or about June 4, 2020, employees were exposed to fall hazards approximately 18 feet high while standing on a ladder jack scaffold and performing residential roofing activities.        Abatement documentation is required for this item in accordance with 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $2227
  • — Z (S) $4453

1926.452 K05

Serious Gravity 10 1 instance 2 exposed
Issued
Jun 22, 2020
Abate by
Aug 15, 2020
Penalty
Initial $4,453 · Current $2,227 Reduced
29 CFR 1926.452(k)(5): Scaffold platforms shall not be bridged one to another.      On or about June 4, 2020, the employer erected a ladder jack scaffold with the boards bridged on to each other. This exposed employees to fall hazards approximately 18 feet high while standing on a ladder jack scaffold and performing residential roofing activities.        Abatement documentation is required for this item in accordance with 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $2227
  • — Z (S) $4453

1926.501 B13

Willful Gravity 10 1 instance 3 exposed
Issued
Jun 22, 2020
Abate by
Aug 15, 2020
Penalty
Initial $29,686 · Current $14,955 Reduced
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure.      On or about June 4, 2020, employees were exposed to fall hazards approximately 18 feet high while engaged in residential roofing activities.  Fall protection was not being utilized while performing roofing operations.     Abatement documentation is required for this item in accordance with 29 CFR 1903.19(d).
Recent events (2)
  • — I (W) $14955
  • — Z (W) $29686

View KOS Remodeling, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344773858.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.