EVERETT, MA —
OSHA Inspection: US CONTRACTING, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of US CONTRACTING, INC. in 23 HENRY STREET, EVERETT, MA 02149 (NAICS 238170). OSHA activity number 344862602.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- US CONTRACTING, INC.
- Site address
- 23 HENRY STREET
- City
- EVERETT
- State
- MA
- ZIP
- 02149
- Mailing
- 6 HERMON ROAD, LYNN, MA 01904
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238170
- Employees
- 4
- Ownership type
- A
Citations
11 citations on file for this inspection.
1926.416 A01
- Issued
- Aug 20, 2020
- Penalty
- Initial $3,856 · Current $1,928 Reduced
General-duty citation text
29 CFR 1926.416(a)(1): Employees were permitted to work in proximity to electric power circuits and were not protected against electric shock by de-energizing and grounding the circuits or effectively guarding the circuits by insulation or other means: (a) Location - 23 Henry Street, Everett, MA: On or about 08/03/2020, old siding was removed and new siding was installed in immediate proximity to the electrical service connection of a single family home without de-energizing and grounding or effectively guarding the circuits by insulation or other means.
Recent events (2)
- — I (S) $1928
- — Z (S) $3856
1926.1053 B12
- Issued
- Aug 20, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(12): Ladders used where the employee or the ladder could contact exposed energized electrical equipment did not have nonconductive siderails: (a) Location - 23 Henry Street, Everett, MA: On or about 08/03/2020, a metal extension ladder was erected and used near the unprotected electrical service connection of a single family home.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1053 B01
- Issued
- Aug 20, 2020
- Penalty
- Initial $5,398 · Current $2,694 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where (a) portable ladder(s) was/were used for access to an upper level landing surface and the ladder's length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder. (a) Location - 23 Henry Street, Everett, MA: On or about 08/03/2020, the ladder used to gain access to the awning over the front door of a single family home did not extend at least three feet past the edge of the awning. This ladder was not long enough to have done so, and was not secured at the top, nor was a grasping device provided. 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: (b) Location - 23 Henry Street, Everett, MA: On or about 08/03/2020, the ladder used to gain access to the highest part of the roof of a single family home did not extend at least three feet past the edge of the roof. This ladder was long enough to have done so.
Recent events (2)
- — I (S) $2694
- — Z (S) $5398
1926.1053 B04
- Issued
- Aug 20, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: (a) Location - 23 Henry Street, Everett, MA: On or about 08/03/2020, the fly section of an extension ladder was separated from its base and erected directly upon its side rails on the landing of the concrete stairs for access to the awning over the front door. (b) Location - 23 Henry Street, Everett, MA: On or about 08/03/2020, extension ladders were erected on the roof of a single family home supported solely by their rungs.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1053 B05 I
- Issued
- Aug 20, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(5)(i): Non-self-supporting ladders were not used at an angle such than the horizontal distance from the top support to the foot of the ladder way approximately one-quarter of the working length of the ladder (the distance along the ladder between the foot and the top support): (a) Location - 23 Henry Street, Everett, MA: On or about 08/03/2020, the angle of the ladder used to gain access to the highest part of the roof of a single family home was too shallow.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1053 B06
- Issued
- Aug 20, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(6): Unsecured ladder(s) were used on surfaces that were not stable and level: (a) Location - 23 Henry Street, Everett, MA: On or about 08/03/2020, an extension ladder was erected on the pitched awning over the front door of a single family home to provide access to the roof.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1053 B07
- Issued
- Aug 20, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(7): Ladder(s) that were unsecured or not provided with slip-resistant feet were used on slippery surfaces: (a) Location - 23 Henry Street, Everett, MA: On or about 08/03/2020, the fly section of an extension ladder was separated from its base and erected directly upon its side rails on the landing of the concrete stairs for access to the awning over the front door.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1053 B15
- Issued
- Aug 20, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(15): Ladders were not inspected by a competent person for visible defects on a periodic basis and after an occurrence that could affect their safe use: (a) Location - 23 Henry Street, Everett, MA: On or about 08/03/2020, metal extension ladders used during siding projects were not periodically inspected for visible defects affecting the structural stability of the ladders.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1053 B16
- Issued
- Aug 20, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately marked in a manner that readily identifies them as defective, or tagged with "Do Not Use" or similar language, and were not withdrawn from service until repaired: (a) Location - 23 Henry Street, Everett, MA: On or about 08/03/2020, a metal extension ladder with a broken rung was not removed from service. (b) 23 Henry Street, Everett, MA: On or about 08/03/2020, a metal extension ladder with a missing cleat was not removed from service.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1053 B18
- Issued
- Aug 20, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(18): Ladder repairs did not restore the ladder to a condition meeting its original design criteria before the ladder was returned to use: (a) Location - 23 Henry Street, Everett, MA: On or about 08/03/2020, the broken rung of a metal extension ladder was field repaired by running a metal rod through the rung and both side rails of the ladder.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1060 A
- Issued
- Aug 20, 2020
- Abate by
- Sep 24, 2020
- Penalty
- Initial $3,856 · Current $1,928 Reduced
General-duty citation text
29 CFR 1926.1060(a): The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would enable each employee to recognize hazards related to ladders and stairways and train each employee in the procedures to be followed to minimize these hazards. (a) Location - 23 Henry Street, Everett, MA: On or about 08/03/2020, employees on a project installing new siding on a single family home have not received effective training in the recognition and avoidance of hazards associated with the use of metal extension ladders.
Recent events (2)
- — I (S) $1928
- — Z (S) $3856
More inspections at US Contracting, INC.
View US Contracting, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238170)
More inspections in MA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344862602.