Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: JMS INTERIORS, INC

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of JMS INTERIORS, INC in BLDG 158, OFFICE 115 NAVAL BASE POINT LOMA, SAN DIEGO, CA 92101 (NAICS 238310). OSHA activity number 344871280.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch JMS Interiors, INC — free Get an email when a new federal OSHA severe-injury report for JMS Interiors, INC is published. One employer, no account, unsubscribe in one click.
Establishment
JMS INTERIORS, INC
Site address
BLDG 158, OFFICE 115 NAVAL BASE POINT LOMA
City
SAN DIEGO
State
CA
ZIP
92101
Mailing
10612 PROSPECT AVENUE SUITE 101, SANTEE, CA 92071
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238310
Employees
7
Ownership type
A

6 citations on file for this inspection.

1910.134 C01

Serious Gravity 1 1 instance 2 exposed
Issued
Aug 24, 2020
Penalty
Initial $1,770 · Current $1,770
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: (Construction Reference 1926.103)  NBPL Building 158: Office 115: Employees performed drywall operations where N95 respirators were required due to the use of Westpac Joint Taping and Topping Joint Compound and Easy Sand 45 which contain crystalline silica. The employer did not have a written respiratory protection program. Employees were exposed to hazards such as respiratory irritants that could exacerbate underlying medical conditions.
Recent events (1)
  • — Z (S) $1770

1910.134 E01

Serious Gravity 1 1 instance 2 exposed
Issued
Aug 24, 2020
Abate by
Nov 2, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: (Construction Reference 1926.103).    NBPL Building 158: Office 115: Employees performed drywall operations where N95 respirators were required due to the use of Westpac Joint Taping and Topping Joint Compound and Easy Sand 45 which contain crystalline silica. The employer did not provide  medical evaluation to employees prior to requiring the use of the N95. This condition may exacerbate an underlying medical condition.
Recent events (1)
  • — Z (S) $0

1910.134 F02

Serious Gravity 1 1 instance 2 exposed
Issued
Aug 24, 2020
Abate by
Nov 2, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator: (Construction Reference 1926.103):  NBPL Building 158: Office 115: Employees performed drywall operations where N95 respirators were required due to the use of Westpac Joint Taping and Topping Joint Compound and Easy Sand 45 which contain crystalline silica. The employer did not perform fit testing prior to initial use of the respirator.  Employees were exposed to hazards such as respiratory irritants that could exacerbate underlying medical conditions.
Recent events (1)
  • — Z (S) $0

1910.134 H02 I

Serious Gravity 1 1 instance 2 exposed
Issued
Aug 24, 2020
Abate by
Sep 11, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.134(h)(2)(i): Respirators were not stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals or  were not packed or stored to prevent deformation of the facepiece and exhalation valve:  (Construction Reference 1926.103)  Building 158: Office 115: Employee(s) performed drywall taping and sanding operations wearing N95 filtering face piece respirators using Westpac Taping and Topping Joint Compound and Easy Sand 45 which contain crystalline silica. The employees stored N95 respirators in non-sealable, open grocery bags and in the open area where particulate silica dust was generated.  Employees were exposed to hazards such as respiratory irritants that could exacerbate underlying medical conditions.
Recent events (1)
  • — Z (S) $0

1910.134 K03

Serious Gravity 1 1 instance 2 exposed
Issued
Aug 24, 2020
Abate by
Sep 11, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.134(k)(3): Training was not provided prior to requiring employees to use a respirator in the workplace:  (Construction Reference 1926.103)  NBPL Building 158: Office 115: Employees performed drywall operations where N95 respirators were required due to the use of Westpac Joint Taping and Topping Compound and Easy Sand 45 which contain crystalline silica. The employer did not provide training on the limitations, use, storage, and disposal of the respirators. Employees were exposed to hazards such as respiratory irritants that could exacerbate underlying medical conditions.
Recent events (1)
  • — Z (S) $0

1910.1200 H01

Other-than-serious 1 instance 2 exposed
Issued
Aug 24, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: (Construction Reference: 1926.59)  NBPL Building 158: Office 115: Employees performed drywall operations using Westpac Joint Taping and Topping Joint Compound and Easy Sand 45 which contain crystalline silica. The employees were unable to identify pictogram markings and other health hazards of the chemicals. The employer did not provide hazardous chemical training prior to the assignment of work. Employees were exposed to inhalation hazards.
Recent events (1)
  • — Z (O) $0

View JMS Interiors, INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344871280.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.