OSHA Inspection: SOUTHWEST RESEARCH INSTITUTE

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of SOUTHWEST RESEARCH INSTITUTE in 6220 CULEBRA RD, SAN ANTONIO, TX 78238 (NAICS 541712). OSHA activity number 344881479.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Southwest Research Institute — free Get an email when a new federal OSHA severe-injury report for Southwest Research Institute is published. One employer, no account, unsubscribe in one click.
Site address
6220 CULEBRA RD
City
SAN ANTONIO
State
TX
ZIP
78238
Mailing
6220 CULEBRA RD, SAN ANTONIO, TX 78238
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
541712
Employees
2754
Ownership type
A

3 citations on file for this inspection.

1910.147 C05 II C 2

Deleted Serious Gravity 5 2 instances 30 exposed
Issued
Oct 29, 2020
Abate by
Nov 18, 2020
Penalty
Initial $11,566 · Current $0 Reduced
29 CFR 1910.147(c)(5)(ii)(C)(2): Tagout devices and their means of attachment were not substantial enough to prevent inadvertent or accidental removal.  a) Building 75, Station 51 (un-numbered):  On or about August 13, 2020, and at times prior thereto, employees were exposed to a caught-in hazard from the test motor not having an adequate lockout device to prevent startup of engine due to the starter switch shutoff handle being removed, allowing bypass of the lockout device.  b) Building 75, Station 53: On or about August 13, 2020, and at times prior thereto, employees were exposed to a caught-in hazard from the test motor not having an adequate lockout device or tag on the fuel line shut-off valve, ensuring that the valve remain in the closed position.
Recent events (3)
  • — F (S) $0
  • — C (S) $11566
  • — Z (S) $11566

1910.147 C05 II D

Other-than-serious Gravity 5 3 instances 30 exposed
Issued
Oct 29, 2020
Abate by
Nov 25, 2020
Penalty
Initial $0 · Current $2,500
29 CFR 1910.147(c)(5)(ii)(D): Lockout devices and tagout devices did not indicate the identity of the employee applying the device(s).  On or about August 13, 2020, and at times prior thereto,  the test stand did not have a LOTO device that indicated the employee who performed the lockout.
Recent events (3)
  • — F (O) $2500
  • — C (S) $0
  • — Z (S) $0

1910.23 B02

Deleted Other-than-serious 1 instance 6 exposed
Issued
Oct 29, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.23(b)(2): Ladder rungs, steps, and cleats were not spaced less than 10 inches (25 cm) and not more than 14 inches (36 cm) apart, as measured between the centerlines of the rungs, cleats, and steps:  Water Cooling Tower, near Building 151: On or about August 13, 2020, and at times prior thereto, employees were exposed to a fall hazard while ascending and descending a fixed ladder attached to the tower that had its first rung spaced above 10-14 inches from the ground level below.