Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: IDEAL SYSTEMS USA, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of IDEAL SYSTEMS USA, INC. in 18 WEST 18TH STREET, ERIE, PA 16501 (NAICS 238160). OSHA activity number 344923156.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Ideal Systems USA, INC. — free Get an email when a new federal OSHA severe-injury report for Ideal Systems USA, INC. is published. One employer, no account, unsubscribe in one click.
Site address
18 WEST 18TH STREET
City
ERIE
State
PA
ZIP
16501
Mailing
70 NORTH 2ND STREET, STROUDSBURG, PA 18360
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
3
Ownership type
A

5 citations on file for this inspection.

1926.502 B01

Serious Gravity 10 1 instance 3 exposed
Issued
Oct 1, 2020
Abate by
Oct 28, 2020
Penalty
Initial $4,048 · Current $1,500 Reduced
29 CFR 1926.502(b)(1): The top edge height of the top rails, or equivalent guardrail system members, was not 42 inches (1.1 m) plus or minus 3 inches (8 cm) above the walking/working level:  A.)  Ideal Systems USA, Inc., 18 West 18th Street, Erie, PA 16501, roof, north side of the structure, on or about September 24, 2020 and times prior thereto:  Employees were performing roofing activities that included, but was not limited to, removing debris.  The top rail of the guardrail system was not installed.  ABATEMENT CERTIFICATION AND DOCUMENTATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation.  This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement. IN ADDITION, abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic, or video evidence or abatement or other written records.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $4048

1926.502 B03

Serious Gravity 10 1 instance 3 exposed
Issued
Oct 1, 2020
Abate by
Oct 28, 2020
Penalty
Initial $0 · Current $0
29 CFR 1926.502(b)(3): Guardrail systems were not capable of withstanding, without failure, a force of at least 200 pounds (890 N) applied within 2 inches (5.1 cm) of the top edge, in any outward or downward direction, at any point along the top edge:  A.)  Ideal Systems USA, Inc., 18 West 18th Street, Erie, PA 16501, roof, west side of the structure, on or about September 24, 2020 and times prior thereto:  Employees were performing roofing activities that included, but was not limited to, removing debris.  The top rail of the guardrail system was deficient in that it was equipped with caution tape and would not meet strength requirements.  ABATEMENT CERTIFICATION AND DOCUMENTATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation.  This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement. IN ADDITION, abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic, or video evidence or abatement or other written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.503 A01

Serious Gravity 1 1 instance 2 exposed
Issued
Oct 1, 2020
Abate by
Nov 5, 2020
Penalty
Initial $1,735 · Current $1,500 Reduced
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards:  A.)  Ideal Systems USA, Inc., 18 West 18th Street, Erie, PA 16501, on or about September 15, 2020 and times prior thereto:  Employees were performing roofing activities that included, but was not limited to, removing debris.  Employees did not have fall protection training.  ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below).  This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $1735

1926.503 B01

Serious Gravity 1 1 instance 1 exposed
Issued
Oct 1, 2020
Abate by
Nov 5, 2020
Penalty
Initial $0 · Current $0
29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer:  A.)  Ideal Systems USA, Inc., 18 West 18th Street, Erie, PA 16501, on or about September 15, 2020 and times prior thereto:  Employees were performing roofing activities that included, but was not limited to, removing debris.  The employer did not certify the fall protection training.  ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below).  This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.501 B10

Repeat Gravity 10 1 instance 1 exposed
Issued
Oct 1, 2020
Abate by
Oct 28, 2020
Penalty
Initial $8,096 · Current $5,000 Reduced
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system.  Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system:  A.)  Ideal Systems USA, Inc., 18 West 18th Street, Erie, PA 16501, roof of the structure, on or about September 9, 2020 and times prior thereto:  Employees were performing roofing activities that included, but were not limited to, cleaning and removal of debris during roofing activities.  Employees were exposed to a fall hazard of over 25-feet.  Employees were not utilizing a means or method of fall protection.  Ideal Systems USA, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(10), which was contained in OSHA inspection number 1355738, citation number 1, item number 2 and was affirmed as a final order on December 14, 2018, with respect to a workplace located at 2711 Columbia Blvd., Bloomsburg, PA  17815.  ABATEMENT CERTIFICATION AND DOCUMENTATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation.  This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement. IN ADDITION, abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic, or video evidence or abatement or other written records.