TUCKER, GA —
OSHA Inspection: E Z FRAMING CO. INC.
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of E Z FRAMING CO. INC. in 2190 NORTHLAKE PARKWAY, TUCKER, GA 30084 (NAICS 238130). OSHA activity number 345015168.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- E Z FRAMING CO. INC.
- Site address
- 2190 NORTHLAKE PARKWAY
- City
- TUCKER
- State
- GA
- ZIP
- 30084
- Mailing
- 7442 PINE BROOK ROAD, STOCKBRIDGE, GA 30281
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 20
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.453 B02 V
- Issued
- Mar 15, 2021
- Penalty
- Initial $6,008 · Current $6,008
General-duty citation text
29 CFR 1926.453(b)(2)(v): A body belt was not worn and/or a lanyard was not attached to the boom or basket when working from an aerial lift: On or about 11/6/2020 at building 3000 where two workers were observed exposed to 9-foot fall hazards to the lower level during framing operations. The workers were operating a JLG 660 SJ aerial lift, S/N 10135260 without connecting to the basket.
Recent events (1)
- — Z (S) $6008
1926.501 B13
- Issued
- Mar 15, 2021
- Penalty
- Initial $7,510 · Current $7,510
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501(b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502: On or about 11/6/2020 at building 3000 where a worker was observed exposed to 50-foot fall hazards to the lower level during roofing operations. The worker was walking the 5/12 pitch, roofing surface without wearing fall protection.
Recent events (1)
- — Z (S) $7510
1926.403 B02
- Issued
- Mar 15, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.403(b)(2):Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: On or about 11/6/2020, throughout the jobsite, employees using extension cord plugged together to power electrical hand tools such as but not limited to air compressor and reciprocal saws were exposed to electrical hazards up to 120 volts, in the employer did not ensure the extension cords were used in its intended application.
Recent events (1)
- — Z (O) $0
1926.404 F06
- Issued
- Mar 15, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.404(f)(6):The path to ground from circuits, equipment, or enclosures was not permanent and continuous: On or about 11/6/2020 at 2190 Northlake Parkway Tucker, GA employees were using equipment, which did not have a grounding path. In three instances, the path to ground from equipment was not permanent, continuous, and effective. The following equipment was missing a path to ground: a. on the third floor, the red extension cord powering the Milwaukee reciprocal saw was missing the grounding pin from the plug; b. on the second floor, at panel 75-157, the yellow extension cord missing grounding pin from the plug; c. on the second floor, at panel 75-157, the orange extension cord missing grounding pin from the plug.
Recent events (1)
- — Z (O) $0
1926.405 G02 IV
- Issued
- Mar 15, 2021
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(g)(2)(iv):Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws: On or about 11/6/2020 at 2190 Northlake Parkway Tucker, GA employees were exposed to electrical hazards up to 120 volts where the employer failed to ensure flexible cords were providing sufficient strain relief. Workers were observed using equipment that did not have effective strain relief at locations including but not limited to the use of : a. Yellow extension cord powered by yellow three way splitter extension cord; b. Yellow extension cord plugged into panel 75-157; c. Yellow/Black extension cord plugged into panel 75-157. with strain relief and
Recent events (1)
- — Z (O) $0
More inspections at E Z Framing CO. INC.
View E Z Framing CO. INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238130)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 345015168.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.