OSHA Inspection: KANE INNOVATIONS, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of KANE INNOVATIONS, INC. in 515 NORTH FRALEY STREET, KANE, PA 16735 (NAICS 332323). OSHA activity number 345021653.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Kane Innovations, INC. — free Get an email when a new federal OSHA severe-injury report for Kane Innovations, INC. is published. One employer, no account, unsubscribe in one click.
Site address
515 NORTH FRALEY STREET
City
KANE
State
PA
ZIP
16735
Mailing
2250 POWELL AVENUE, ERIE, PA 16506
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332323
Employees
22
Ownership type
A

1 citation on file for this inspection.

1910.212 A03 II

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 20, 2021
Abate by
May 14, 2021
Penalty
Initial $10,533 · Current $6,000 Reduced
29 CFR  1910.212(a)(3)(ii): The point of operation of machines whose operation exposes an employee to injury, was not guarded:  a) production floor, on or about November 3, 2020, the point of operation on the Cincinnati hydraulic press brake was inadequately guarded.  The Triad Superlight VI light curtain was not operating properly to protect operators from the pinch-point created by the hydraulic press during normal operations.  On or about November 3, 2021, an employee experienced amputation injuries to the right hand while operating the press when the light curtain/controller system failed.
Recent events (2)
  • — I (S) $6000
  • — Z (S) $10533

View Kane Innovations, INC.'s full OSHA safety record →